Required straight pipe length:
10D minimum on upstream side and
5D minimum on downstream side
Note: D is a nominal meter size.
Fluid conductivity: 100µS/cm minimum
Fluid temperature: 32 to 131 °F (0 to 55 °C )
Ambient temperature: 14 to 122 °F
Dimensions and Weights: See figures 3 to 5.
Power supply:
100 to 120 Vac (80 to 132 Vac), 50/60Hz
Power consumption: 50VA (30W) or less
■Model LF502 Detector
Meter sizes: 6” (150 mm ), 8” (200 mm ), 10” (250
mm), 12” (300 mm ), 14” (350 mm ), 16” (400 mm ), 20” (500 mm ), 24”(600 mm )
Fluid pressure:
0 psi or 0 bar (0 MPa) to the pressure limited by flange standard
Connection flange standards:
ANSI 150, JIS 10K
Structure:
IP67 and NEMA 4X Watertight (std. )
IP68 and NEMA 6P Submersible (opt.)
Coating: Phthalic acid resin coating,
Principal materials:
Case — carbon steel
Measuring pipe — 304 stainless steel Linings — The following are the standards:
Meter size | Standard specification |
6” to 16” (150 to 400mm ) | EPDM rubber |
20” & 24” (500 & 600mm ) | Chloroprene rubber |
Electrodes — 316L stainless steel (std.) Grounding rings — The following are the
standards.
Meter size | Standard specification |
6” to 16” (150 to 400mm ) | 316 stainless steel |
20” & 24” (500 & 600mm ) | 304 stainless steel |
See Table 1 for optional materials and other related information.
Coating: phthalic acid resin coating (std.),
Cable connection port:
Cable glands: Provided as standard, R(PT) 1/2 male screw.
Applicable diameter: 0.433 to 0.512 inch (11
to 13mm )
■Model LF232*F converter
Input signals
Analog signal — the voltage signal from detector, proportional to process flow rate.
Digital input DI (opt.)
(added when 9th digit of specification code is ”3”) Voltage level: High level 20 to 30 V dc
Low level 2 V dc or less Input resistance: 2.7 kΩ
Number of inputs: 2 points (DI1 and DI2)
DI functions:
For digital input function, either of the following functions can be selected.
•Range switching
One Digital Input is used: switching between large and small ranges of forward/reverse,
Two Digital Inputs are used: switching between ranges of single direction,
•Totalizer control input
Totalizer Start/Stop control or Reset/Start
•Output hold input
Fixed with set value for current output and pulse output (loop check)
•Zero adjustment
Starts zero adjustment
Output signals
Current output:
Digital output (DO) — One point (std.) and three more point is optionally available as follows.
Digital output DO1 (std.):
Output type: Transistor open collector
Number of outputs: One point
Output capacity : 30Vdc, 200mA maximum
Digital output DO2~DO4 (opt.)
(Added when 9th digit of specification code is “3”) Out put type: Solidstate relay output (non polarity) Number of outputs: 3 points
Output capacity: 150Vdc, 150mA maximum or 150Vac (peak to peak), 100mA maximum
DO
• Totalizer pulse output
DO1 or DO2 can be selected (Forward direction pulse and reverse direction pulse can be assigned