Communications output :
•HART (std.) — Digital signal is superimposed on
Conforms to HART protocol Load resistance: 240 to 750Ω Load capacitance: 0.25µF maximum Load inductance: 4mH maximum
•PROFIBUS(opt.)
Protocol:
Baud rate: 31.25kbps
Bus voltage:
Consumption electric current of bus: less than 16mA
Manufacture
Standard
Slave address:
Profile: Profile Ver.3.01 for Process Control Devices
Function blocks: AI(Flow)×1 , Totalizer×1
LCD display:
Full
The data on the LCD inside the converter can rotate to 90, 180, and 270 degrees by a software, without rotating the indicator itself. (Combined type only)
Parameter settings — Parameters can be set as follows:
•IR Switches: Three key switches are provided to set configuration parameters.
•Digital communication: The AF900
terminal or PROFIBUS is needed to set parameters.
•Zero adjustment: Zero point adjustment can be started by pressing the switch in the converter.
•Damping: 0.5 to 60 seconds (selectable in one second increments)
“Field
Zero span calibration tool allows unit to be
Conditions when power fails:
Parameter setting values are stored in
•Current output: 0mAdc
•Digital output: OFF
•LCD display: No display
•PROFIBUS: No communication
Power supply:
One of the following can be selected:
•100 to 240Vac, 50/60Hz (std.) (allowable voltage 80 to 264Vac)
•24Vdc (allowable voltage 18 to 36Vdc)
•110Vdc (allowable voltage 90 to 130Vdc)
Surge protection:
Arresters are installed in the power supply and a current signal output circuit to help protect the meter from lightning and improve personnel safety.
Case: Aluminum alloy (equal to IP 67)
Coating: Acrylic
Cable connection port:
Cable glands —
Provided as standard, OD of 11 to 13mm
Material Nylon 66
G (PF) 1/2 male screws
Applicable diameter —
0.433 to 0.512 inch (11 to 13mm)
Note: When PROFIBUS option is specified, cable gland size is φ 6~8mm for signal cable, φ11~13mm for power cable
Vibration resistance:
No resonance to the following levels of vibration:
•10 to 150Hz with acceleration of 9.8m/s2
•Vibration of 30Hz with 29.4 m/s2 in 4h in each direction will not cause any defect to unit.
Note: Avoid using the flowmeter in an environment with constant vibration.
Dimensions :
See Figure 5
MTBF:
Converter: 220,000 hours (25 years) at 77 °F (25 °C) based on strict military specification
Detector: 350,000 hours (40 years) at 77 °F (25 °C) based on strict military specification