3 Diagnostic Programs 3.11Error Codes and Description
30
32bits Video Mode Test
Error As above. As above.
31xx Audio
01 Audio Play Fail Cannot play music.
Check the Audio connection,
replace the external fixture, and
repeat the test.
02 Record Fail Cannot record. As above.
11xx LPT
01 Data Register Error The data register can not perform
normally.
Check the external fixture and
BIOS setup, and repeat the test.
02 Control Register Error The control register can not
perform normally. As above.
03
Does not Support ECP
Mode(Ver3.20) LPT does not support ECP mode. Check the BIOS setup, and repeat
the test.
04 FIFO Test Error
LPT cannot perform normally
under FIF0 TEST mode (ECP
internal mode).
As above.
05 IRQ Active Error
1.LPT IRQ cannot be activated.
2. The external fixture does not
match with the chosen version.
Check the external fixture and
BIOS setup, and repeat the test.
06 No Fixture On The Port No external fixtures on LPT port. As above.
09
CTR/STR Connection
Error
1. There is OC (Open Circuit) or
SC (Short Circuit) on the LPT
port CTR/STR.2. The external
fixture does not match with the
chosen version.
Check the external fixture and the
port pins, and repeat the test.
10
DTR/STR Connection
Error As above. As above.
11 Toshiba Fixture Error As above. As above.
08xx LAN Card
01
PCI bus Error during
device ID test Don’t Scan PCI device Don’t support PCI BIOS
02
PCI Ethernet card not
present during device ID
test
Don’t find Net card Please insert Net cad
03
Intel PCI Ethernet card
not present during MAC
test
Don’t found Net Card, This Card
can’t be Read MAC by this
method
Please update net card or use
other method
09xx Keyboard
01
Keyboard Map & Stroke
Test Fail
Keyboard Map & Stroke Test
fails.
Check the KBD connection and
repeat the test.
03 Clock Line Test Fail Clock Line Test fails. As above.
64 Satellite M40/M45 TECRA A4 Dynabook Vx/4 Maintenance Manual