3.11Error Codes and Description 3 Diagnostic Programs
04 Data Line Test Fail Data Line Test fails. As above.
05xx Mouse
01 Touch Pad Test Fail Touch Pad Test Fail Check the mouse connection and
repeat the test.
14xx IrDA Test
01 2400BPS Test Error
Failure with the infrared port or
the configuration program is not
executed.
Rerun the configuration program
or check the infrared port.
02 9600BPS Test Error As above. As above.
03 19200BPS Test Error As above. As above.
04 38400BPS Test Error As above. As above.
05 57600BPS Test Error As above. As above.
06 115200BPS Test Error As above. As above.
07 0.576MBPS Test Error As above. As above.
08 1.152MBPS Test Error As above. As above.
09 4.000MBPS Test Error As above. As above.
10 Connect time out
Failure with the infrared port or
the configuration program is not
executed.
Rerun the configuration program
or check the infrared port. Check
the master.
30xx MemoryCard
08 Check PCI Device Fail No Memory Card is inserted or
the Memory Card is damaged.
Replace the Memory Card and
repeat the test.
09 Start Flash Media Tests
Fail As above. As above.
10 Verifying Firmware
loaded Fail As above. As above.
11 MMC or SD Media Card
Present Fail As above. As above.
28xx 1394
01 Can not find IEEE1394 Don’t support 1394.
Satellite M40/M45 TECRA A4 Dynabook Vx/4 Maintenance Manual 65