3. OPERATIONAL DESCRIPTION

3.1 General Operation

The ADU is a unit which turns over printed paper. Installation of the unit enables duplex printing on paper. No paper can be stacked in the ADU.

3.2 Block Diagram

 

 

 

 

 

 

 

 

 

 

PFC

CN203

 

 

CN211

 

 

 

 

PWA

CN204

+24V

 

CN212

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ADU PWA

CN216 CN215

CN217 CN214 CN213

ADU

FDMA-D

M ADU motor (Lower)

EXMA-D

M ADU motor (Upper)

ADUFL

ADU paper jam sensor (Lower)

ADUFU

ADU paper jam sensor (Upper)

ADUCOVSW

ADU cover open switch

ADU 03-02-01

The ADU has three sensors and two motors as shown above. One-side-printed paper passes through the ADU unit to be turned over and returned to the copier. The motor drive circuits (IC1, IC2) only are installed on the ADU PWA.

The motor signals (EXM-A - D, FDM-A - D) are amplified by IC1 and IC2 and drive the motors. The signal of each sensor passes through the ADU PWA and is connected as it is to the PFC PWA.

October 2000 © TOSHIBA TEC

3 - 1

MD-0101 OPERATIONAL DESCRIPTION

Page 8
Image 8
Toshiba MD-0101 manual Operational Description, General Operation, Block Diagram