Chapter 2 Troubleshooting Procedures
2.16 Camera Troubleshooting structed.
Procedure 1: Camera Execution Check
ck
Procedure 2 Connect Check and Replacement Check
The CCD cable is connected to system board integrated with LCD cable. If camera
malfunctions, its connection may be defective or LCD/CCD cable and system board may be
faulty.
Check 1 Make sure the other side of CCD cable is correctly and firmly inserted to the CN3
in MB. If the problem still occurs, perform Check 2.
To check if the computer’s Camera is malfunctioning or not, follow the troubleshooting
procedure below as in
Procedure 2: Connect Check and Replacement Check
Procedure 1 Camera Execution Che
Open photo/video tool to look if there is an image. If not, go to Procedure 2.
Check 2 CCD cable may be faulty. Replace it with a new one. If the problem still occurs,
perform Check 3.
heck 3 Camera may be faulty. Replace it with a new one following the instruction in
Chapter 4.
Check 4 System board may be faulty. Replace it with a new one following the instruction in
Chapter 4.
C
Satellite L600/L640/L645, Satellite Pro L600/Pro L640/Pro L645 Maintenance Manual (960-Q08)