GRUPAd.o.o.
Scheduled operations
11
EN
7Set what is to be operated at the time which was
set in step 6.
* The settings can be established in any sequence.
The functions will differ depending on the model and
system.
I. Selecting and setting operation/stop
Each time the button (48) is pushed, what
appears on the timer function display changes in
the following sequence. Stop pushing the button
when the desired operation blinks on the display.
II. Selecting and setting the operation mode
Each time the button (34) is pushed, what
appears on the operation mode display (1)
changes in the following sequence. Stop pushing
the button when the operation mode blinks on the
display.
III.Setting the temperature
Each time the TEMP and buttons (49) are
pushed, what appears on the numeric display
changes in the following sequence. Stop pushing
the buttons when the target temperature to be set
blinks on the display.
IV.Setting the restriction on the button operations
• Each time the button (34) is pushed while the
button (43) is held down, the central control
display changes from off to blinking or vice versa.
To place the restriction on the button operations,
ensure that the display is blinking.
* The button (32), button (34) and
TEMP and buttons (49) are the buttons
whose operation will be restricted by this setting.
For further details, refer to the “Selecting the
remote controller functions” section.
V. Setting the save operation
Each time the button (38) is pushed, the
numeric display and save operation display
change in the following sequence. Stop pushing
the button when the desired save operation mode
(mode 0 to 3) blinks on the display.
8Push the button (42), and enter all the items in
steps I to V above and the operation time
together.
• The display of all the setting items changes from
blinking to lighted.
9In addition:
I. To input the settings into the different program
number for the same day of the week, repeat the
operations from step 4.
II. To move to a different day of the week and input
the program, repeat the operations from step 2.
10
Finally, push the button (46) to return to the
original screen.
• An underbar is display ed under the selected day of
the week.
Operation
continue
(No display)
Operation
stop
Operation
start
Auto
Operation mode
Heating Dry
(No display)
Fan Cooling
or
Push 4seconds
or more
Push 4 seconds or more
Frost protection
operation
Save operation
mode Description
Mode0 No save operation
Mode1 Save operation with 75% upper limit
Mode2 Save operation with 50% upper limit
Mode3 Compressor shutdown
Mode 0 Mode 1 Mode 2 Mode 3
MB FRIGO Grupa d.o.o., Bani 81, 10010 Zagreb, www.toshiba.hr, e-mail: toshiba@mbfrigo.hr