GRUPAd.o.o.

19

EN
Selecting the remote controller functions
• Change the settings of the remote controller functions
as required by taking the steps below.
How to change the remote controller functions
1While operation is shut down, push the button
(43) and button (48) together for at least 4
seconds.
• The numeric displays and display blink,
and the fixed louvers display lights.
2Push the TEMP and buttons (49).
• Repeatedly push the buttons unt il the setting to be
changed blinks on the display.
3Push the TIME and buttons (40).
• Repeatedly push the buttons unt il the setting to be
changed blinks on the display.
4Push the button (42). Then push the button
(43) to return to the original screen.
• When the button (42) is pushed, the numeric
displays and display stop blinking and
light up, and when the button (43) is pushed
again, they go off.
Items to be set
• 24-hour/12-hour display setting <code No.10>
– The 24-hour display or 12-hour (AM/PM) display
can be selected for the clock which is displayed on
the remote controller.
– This item’s selection is also reflected on the clock
displayed on the clock setting screen and program
input screen.
• Restriction on button operations <code No.12>
This item sets the range of the restriction placed on
the button operations which can be applied while
scheduled operations are being performed.
Setting: 0000 (factory setting)
Code No.12
O: Can be operated.
X: Cannot be operated.
• Display/non-display of clock <code no.13>
This item selects and sets whether the day of the week
and clock time are to be displayed.
Setting: 0000 (factory setting)
Code No.13
O: Display X: No display
• Selection of operation when power is restored after a
power outage <code No.14>
This item selects the operation to be performed when
power is restored after a power outage occurred
during a scheduled operation.
0000: No operations are performed when the power is
restored, and the scheduled operation is resumed as
soon as the program time is reached after the power
has been restored. (When the power is restored, the
scheduled operation is based on the operation of the
indoor units.)
0001: If there was a programmed operation during the
power outage, that operation is performed when the
program is resumed. If there is no programmed
operation or if the “Continue xx” setting is in place, the
operation prior to the power outage is resumed.

Selecting the functions using the DIP

switches of the remote controller

• The following functions can b e selected using the DIP
switches on the remote controller’s circuit board.
Setting procedure
• Open the back cover of the remote controller, and
select the functions using the DIP switches located at
the bottom left of the circuit board.
• After establishing the settings, turn the ground fault
interrupter off and then back on.
Setting items
• Remote controller header/follower setting: Bit 1
When operating the air conditioner using two remote
controllers, set one of the controls to be the follower.
* Set the remote controller used as the schedule timer
to be the header.
• Operation function setting: Bit 2
One of the following three operation functions can be
selected and set.
1.Scheduled operation function
2.Timer operation function
3.No scheduled or timer operation function
Setting Description
0000:
0001:
24-hour display (factory setting)
12-hour (AM/PM) display
Setting [ON/OFF] [MODE] [TEMP.]
0000 O O O
0001 X O X
0002 X X X
0003 O X X
0004 O X O
Setting
Scheduled operation
underway
Scheduled operation
in standby
Air
conditioner
now
operating
Air
conditioner
now shut
down
Air
conditioner
now
operating
Air
conditioner
now shut
down
0000 O O O O
0001 X X X X
0002 O O X X
0003 O X X X
0004 O O O X
0005 O X O X
MB FRIGO Grupa d.o.o., Bani 81, 10010 Zagreb, www.toshiba.hr, e-mail: toshiba@mbfrigo.hr