TIC-LF232A
7
Table 1. Specification Code for converters (LF232) Model Specification Code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 Contents
L F 2 3 2
Separate type converter
A
Purpose
Standard
A
B
Compatible detectors (Note1,2,3)
Medium to small-size detectors:
Meter size 1/10” to 18” (2.5 to 450 mm)
Large-size detectors:
Meter size 28” to 120” (700 to 3000 mm)
C
E
Mounting nuts and bolts
Panel, wall mounting (BNP material : SUS304)
Pipe mounting (BNP material : SUS304)
1
3
Digital input/output
Current output
+ Digital output points (1 point)
Current output
+ Digital output points (4 points) + Digital input points (2 points)
1
Communication function
HART communication
1
2
Power supply
100Vac-240Vac, 50/60Hz (Note 2)
24Vdc (Note 3)
A
Standard
For combination with detectors not listed below, contact Toshiba.
Applicable
detector code
Applicable
detector
Applicable detector
(discontinued model) Replaceable converters
A LF470 type
334,
335 type (Converters of
types shown right)
372, LF200, LF220, LF420,
LF230* A type
B LF150 type
337,
335 type (Converters of
types shown right)
373, 378, LF230* B type
Note 2: When the 7th digit is “B” and power supply specification code is “1”, power supply specification is 100 to 120VAC. Note 3: 24VDC can be specified only when the 7th digit is “A”.