General
Data
TUY-R9V PRODUCT SPECIFICATIONS1
MODEL | TUY060R9V3V | TUY080R9V3V | TUY100R9V4V | TUY120R9V5V |
RATINGS2 |
|
|
|
|
1st Stage Input BTUH | 39000 | 52000 | 65000 | 78000 |
1st Stage Capacity BTUH (ICS)3 | 37000 | 49000 | 62000 | 74000 |
2nd Stage Input BTUH | 60000 | 80000 | 100000 | 120000 |
2nd Stage Capacity BTUH (ICS)3 | 56000 | 73000 | 93000 | 112000 |
AFUE (ICS) | 93.0 | 92.5 | 93.0 | 92.5 |
Temp. Rise | 35 - 65 | 35 - 65 | 35 - 65 | 40 - 70 |
BLOWER DRIVE | DIRECT | DIRECT | DIRECT | DIRECT |
10 x 8 | 10 x 8 | 10 x 10 | 10 x 10 | |
No. Used | 1 | 1 | 1 | 1 |
Speeds (No.) | VARIABLE | VARIABLE | VARIABLE | VARIABLE |
CFM vs. in. w.g. | SEE FAN PERF. TABLE | SEE FAN PERF. TABLE | SEE FAN PERF. TABLE | SEE FAN PERF. TABLE |
Motor HP | 1/2 | 1/2 | 1 | 1 |
R.P.M. | VARIABLE | VARIABLE | VARIABLE | VARIABLE |
Volts/Ph/Hz | 115/1/60 | 115/1/60 | 115/1/60 | 115/1/60 |
COMBUSTION FAN - TYPE | CENTRIFUGAL | CENTRIFUGAL | CENTRIFUGAL | CENTRIFUGAL |
Drive - No. Speeds | DIRECT - VARIABLE | DIRECT - VARIABLE | DIRECT - VARIABLE | DIRECT - VARIABLE |
Motor HP - RPM | 1/15 - 5000 | 1/15 - 5000 | 1/15 - 5000 | 1/25 - 5000 |
Volts/Ph/Hz | 115/1/60 | 115/1/60 | 115/1/60 | 115/1/60 |
FL Amps | 1.1 | 1.1 | 1.1 | 1.1 |
FILTER — Furnished? | YES | YES | YES | YES |
Type Recommended | HIGH VELOCITY | HIGH VELOCITY | HIGH VELOCITY | HIGH VELOCITY |
Filter | 1 X 17 X 25 X 1 | 1 X 17 X 25 X 1 | 1 - 20 X 25 X 1 | 1 - 24 X 25 X 1 |
VENT — Size (In.) | 2 ROUND | 2 ROUND | 3 ROUND | 3 ROUND |
HEAT EXCHANGER |
|
|
|
|
Type | ALUMINIZED STEEL TYPE 1 | ALUMINIZED STEEL TYPE 1 | ALUMINIZED STEEL TYPE 1 | ALUMINIZED STEEL TYPE 1 |
|
|
|
| |
Gauge (Fired) | 20 | 20 | 20 | 20 |
ORIFICES — Main |
|
|
|
|
Nat. Gas. Qty. — Drill Size | 3 - 45 | 4 - 45 | 5 - 45 | 6 - 45 |
L.P. Gas Qty. — Drill Size | 3 - 56 | 4 - 56 | 5 - 56 | 6 - 56 |
GAS VALVE | REDUNDANT - TWO STAGE | REDUNDANT - TWO STAGE | REDUNDANT - TWO STAGE | REDUNDANT - TWO STAGE |
DIRECT IGNITION DEVICE |
|
|
|
|
Type | HOT SURFACE IGNITER | HOT SURFACE IGNITER | HOT SURFACE IGNITER | HOT SURFACE IGNITER |
BURNERS — Type | ||||
Number | 3 | 4 | 5 | 6 |
POWER CONN. — V/Ph/Hz4 | 115/1/60 | 115/1/60 | 115/1/60 | 115/1/60 |
Ampacity (In Amps) | 8.4 | 8.4 | 11.4 | 11.4 |
Max. Overcurrent Protection (Amps) | 15 | 15 | 15 | 15 |
PIPE CONN. SIZE (IN.) | 0.50 | 0.50 | 0.50 | 0.50 |
DUCT CONN. | SEE OUTLINE DRAWING | SEE OUTLINE DRAWING | SEE OUTLINE DRAWING | SEE OUTLINE DRAWING |
DIMENSIONS | H X W X D | H X W X D | H X W X D | H X W X D |
Crated (In.) | ||||
Uncrated | SEE OUTLINE DRAWING | SEE OUTLINE DRAWING | SEE OUTLINE DRAWING | SEE OUTLINE DRAWING |
WEIGHT |
|
|
|
|
Shipping (Lbs.)/Net (Lbs.) | 158/146 | 158/148 | 171/160 | 205/193 |
1Central Furnace heating designs are certified by AGA and CSA.
2For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3Based on U.S. government standard tests.
4The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.