Trane 120R9V, 080, XV 90, 100 manual General Data, TUY-R9VPRODUCT SPECIFICATIONS1

Models: 100 120R9V XV 90 080

1 16
Download 16 pages 43.98 Kb
Page 6
Image 6
General

General

Data

TUY-R9V PRODUCT SPECIFICATIONS1

MODEL

TUY060R9V3V

TUY080R9V3V

TUY100R9V4V

TUY120R9V5V

RATINGS2

 

 

 

 

1st Stage Input BTUH

39000

52000

65000

78000

1st Stage Capacity BTUH (ICS)3

37000

49000

62000

74000

2nd Stage Input BTUH

60000

80000

100000

120000

2nd Stage Capacity BTUH (ICS)3

56000

73000

93000

112000

AFUE (ICS)

93.0

92.5

93.0

92.5

Temp. Rise (Min.-Max.) °F.

35 - 65

35 - 65

35 - 65

40 - 70

BLOWER DRIVE

DIRECT

DIRECT

DIRECT

DIRECT

Dia.-Width (In.)

10 x 8

10 x 8

10 x 10

10 x 10

No. Used

1

1

1

1

Speeds (No.)

VARIABLE

VARIABLE

VARIABLE

VARIABLE

CFM vs. in. w.g.

SEE FAN PERF. TABLE

SEE FAN PERF. TABLE

SEE FAN PERF. TABLE

SEE FAN PERF. TABLE

Motor HP

1/2

1/2

1

1

R.P.M.

VARIABLE

VARIABLE

VARIABLE

VARIABLE

Volts/Ph/Hz

115/1/60

115/1/60

115/1/60

115/1/60

COMBUSTION FAN - TYPE

CENTRIFUGAL

CENTRIFUGAL

CENTRIFUGAL

CENTRIFUGAL

Drive - No. Speeds

DIRECT - VARIABLE

DIRECT - VARIABLE

DIRECT - VARIABLE

DIRECT - VARIABLE

Motor HP - RPM

1/15 - 5000

1/15 - 5000

1/15 - 5000

1/25 - 5000

Volts/Ph/Hz

115/1/60

115/1/60

115/1/60

115/1/60

FL Amps

1.1

1.1

1.1

1.1

FILTER — Furnished?

YES

YES

YES

YES

Type Recommended

HIGH VELOCITY

HIGH VELOCITY

HIGH VELOCITY

HIGH VELOCITY

Filter (No.-Size-Thk.)

1 X 17 X 25 X 1

1 X 17 X 25 X 1

1 - 20 X 25 X 1

1 - 24 X 25 X 1

VENT — Size (In.)

2 ROUND

2 ROUND

3 ROUND

3 ROUND

HEAT EXCHANGER

 

 

 

 

Type -Fired

ALUMINIZED STEEL TYPE 1

ALUMINIZED STEEL TYPE 1

ALUMINIZED STEEL TYPE 1

ALUMINIZED STEEL TYPE 1

-Unfired

 

 

 

 

Gauge (Fired)

20

20

20

20

ORIFICES — Main

 

 

 

 

Nat. Gas. Qty. — Drill Size

3 - 45

4 - 45

5 - 45

6 - 45

L.P. Gas Qty. — Drill Size

3 - 56

4 - 56

5 - 56

6 - 56

GAS VALVE

REDUNDANT - TWO STAGE

REDUNDANT - TWO STAGE

REDUNDANT - TWO STAGE

REDUNDANT - TWO STAGE

DIRECT IGNITION DEVICE

 

 

 

 

Type

HOT SURFACE IGNITER

HOT SURFACE IGNITER

HOT SURFACE IGNITER

HOT SURFACE IGNITER

BURNERS — Type

IN-SHOT

IN-SHOT

IN-SHOT

IN-SHOT

Number

3

4

5

6

POWER CONN. — V/Ph/Hz4

115/1/60

115/1/60

115/1/60

115/1/60

Ampacity (In Amps)

8.4

8.4

11.4

11.4

Max. Overcurrent Protection (Amps)

15

15

15

15

PIPE CONN. SIZE (IN.)

0.50

0.50

0.50

0.50

DUCT CONN.

SEE OUTLINE DRAWING

SEE OUTLINE DRAWING

SEE OUTLINE DRAWING

SEE OUTLINE DRAWING

DIMENSIONS

H X W X D

H X W X D

H X W X D

H X W X D

Crated (In.)

41-3/4 X 19-1/2 X 30-1/2

41-3/4 X 19-1/2 X 30-1/2

41-3/4 X 23 X 30-1/2

41-3/4 X 26-1/2 X 30-1/2

Uncrated

SEE OUTLINE DRAWING

SEE OUTLINE DRAWING

SEE OUTLINE DRAWING

SEE OUTLINE DRAWING

WEIGHT

 

 

 

 

Shipping (Lbs.)/Net (Lbs.)

158/146

158/148

171/160

205/193

1Central Furnace heating designs are certified by AGA and CSA.

2For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.

3Based on U.S. government standard tests.

4The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

6

Pub. No. 22-1682-05-0802 (EN)

Page 6