Performance
Data
TUY080R9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR | AIRFLOW |
| DIP SWITCH SETTING |
|
|
| EXTERNAL STATIC PRESSURE |
| |||||||
UNIT SIZE | SETTING |
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
(TONS) | (See Notes) | SW 1 |
| SW 2 | SW 3 |
| SW 4 |
| 0.1 |
| 0.3 | 0.5 | 0.7 |
| 0.9 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LOW | ON |
| ON | OFF |
| ON | CFM | 750 |
| 750 | 750 | 720 |
| 710 |
| (350 CFM/TON) |
|
| WATTS | 84 |
| 122 | 154 | 185 |
| 221 | ||||
|
|
|
|
|
|
|
|
| |||||||
2.0 | NORMAL | ON |
| ON | OFF |
| OFF | CFM | 840 |
| 840 | 840 | 840 |
| 820 |
(400 CFM/TON) |
|
| WATTS | 109 |
| 146 | 181 | 226 |
| 264 | |||||
|
|
|
|
|
|
|
|
| |||||||
| HIGH | ON |
| ON | ON |
| OFF | CFM | 940 |
| 940 | 940 | 940 |
| 940 |
| (450 CFM/TON) |
|
| WATTS | 136 |
| 177 | 215 | 274 |
| 318 | ||||
|
|
|
|
|
|
|
|
| |||||||
| LOW | OFF |
| ON | OFF |
| ON | CFM | 850 |
| 850 | 870 | 890 |
| 890 |
| (350 CFM/TON) |
|
| WATTS | 113 |
| 150 | 200 | 250 |
| 295 | ||||
|
|
|
|
|
|
|
|
| |||||||
2.5 | NORMAL | OFF |
| ON | OFF |
| OFF | CFM | 960 |
| 990 | 1000 | 1020 |
| 1010 |
(400 CFM/TON) |
|
| WATTS | 150 |
| 200 | 230 | 305 |
| 350 | |||||
|
|
|
|
|
|
|
|
| |||||||
| HIGH | OFF |
| ON | ON |
| OFF | CFM | 1080 |
| 1110 | 1120 | 1120 |
| 1080 |
| (450 CFM/TON) |
|
| WATTS | 195 |
| 255 | 315 | 365 |
| 390 | ||||
|
|
|
|
|
|
|
|
| |||||||
| LOW | ON |
| OFF | OFF |
| ON | CFM | 1020 |
| 1020 | 1040 | 1050 |
| 1050 |
| (350 CFM/TON) |
|
| WATTS | 175 |
| 225 | 280 | 330 |
| 375 | ||||
|
|
|
|
|
|
|
|
| |||||||
3.0 | NORMAL | ON |
| OFF | OFF |
| OFF | CFM | 1170 |
| 1180 | 1200 | 1200 |
| 1130 |
(400 CFM/TON) |
|
| WATTS | 240 |
| 300 | 365 | 415 |
| 420 | |||||
|
|
|
|
|
|
|
|
| |||||||
| HIGH | ON |
| OFF | ON |
| OFF | CFM | 1290 |
| 1320 | 1350 | 1340 |
| 1150 |
| (450 CFM/TON) |
|
| WATTS | 310 |
| 410 | 470 | 520 |
| 440 | ||||
|
|
|
|
|
|
|
|
| |||||||
| LOW | OFF |
| OFF | OFF |
| ON | CFM | 1170 |
| 1190 | 1210 | 1210 |
| 1100 |
| (350 CFM/TON) |
|
| WATTS | 250 |
| 315 | 370 | 435 |
| 405 | ||||
|
|
|
|
|
|
|
|
| |||||||
3.5 | NORMAL | OFF |
| OFF | OFF |
| OFF | CFM | 1360 |
| 1390 | 1400 | 1360 |
| 1210 |
(400 CFM/TON) |
|
| WATTS | 365 |
| 445 | 500 | 535 |
| 475 | |||||
|
|
|
|
|
|
|
|
| |||||||
| HIGH | OFF |
| OFF | ON |
| OFF | CFM | 1360 |
| 1390 | 1400 | 1350 |
| 1180 |
| (450 CFM/TON) |
|
| WATTS | 355 |
| 450 | 520 | 535 |
| 460 | ||||
|
|
|
|
|
|
|
|
|
NOTES: Continuous Fan is with Thermostat Fan Switch on and Dip Switches 5 and 6 in the "ON" position.
1.At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2.LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
TUY080R9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
|
|
|
|
| 1st Stage Capacity = | 49,000 |
|
| ||
|
|
|
|
| 2nd Stage Capacity = | 73,000 |
|
| ||
| AIRFLOW | DIP SWITCH SETTING |
|
| EXTERNAL STATIC PRESSURE |
| ||||
|
|
|
|
|
|
|
|
| ||
| SETTING | SW 7 | SW 8 |
| 0.1 | 0.3 | 0.5 | 0.7 | 0.9 | |
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
| CFM | 800 | 800 | 800 | 800 | 800 | |
| LOW | ON | ON | TEMP. RISE | 56 | 56 | 56 | 56 | 56 | |
|
|
|
| WATTS | 105 | 140 | 180 | 220 | 265 | |
|
|
|
| CFM | 860 | 880 | 890 | 920 | 910 | |
HEATING | MEDIUM LOW | OFF | ON | TEMP. RISE | 52 | 51 | 50 | 48 | 49 | |
|
|
| WATTS | 115 | 165 | 215 | 265 | 320 | ||
1ST |
|
|
| |||||||
|
|
| CFM | 960 | 990 | 1000 | 1020 | 1010 | ||
STAGE |
|
|
| |||||||
NORMAL ** | ON | OFF | TEMP. RISE | 46 | 45 | 44 | 44 | 44 | ||
| ||||||||||
|
|
|
| WATTS | 150 | 200 | 230 | 310 | 350 | |
|
|
|
| CFM | 1080 | 1110 | 1120 | 1120 | 1080 | |
| HIGH | OFF | OFF | TEMP. RISE | 41 | 40 | 40 | 40 | 41 | |
|
|
|
| WATTS | 195 | 255 | 315 | 365 | 390 | |
|
|
|
| CFM | 1100 | 1100 | 1120 | 1120 | 1090 | |
| LOW | ON | ON | TEMP. RISE | 62 | 62 | 61 | 61 | 63 | |
|
|
|
| WATTS | 205 | 260 | 320 | 370 | 400 | |
|
|
|
| CFM | 1210 | 1240 | 1260 | 1260 | 1130 | |
HEATING | MEDIUM LOW | OFF | ON | TEMP. RISE | 57 | 55 | 54 | 54 | 61 | |
|
|
| WATTS | 265 | 340 | 410 | 470 | 430 | ||
2ND |
|
|
| |||||||
|
|
| CFM | 1360 | 1390 | 1400 | 1360 | 1210 | ||
STAGE |
|
|
| |||||||
NORMAL ** | ON | OFF | TEMP. RISE | 50 | 49 | 49 | 50 | 57 | ||
| ||||||||||
|
|
|
| WATTS | 365 | 445 | 500 | 535 | 475 | |
|
|
|
| CFM | 1360 | 1390 | 1400 | 1350 | 1180 | |
| HIGH | OFF | OFF | TEMP. RISE | 50 | 49 | 49 | 51 | 58 | |
|
|
|
| WATTS | 355 | 450 | 520 | 535 | 465 |
NOTES:
** Factory setting
8 | Pub. No. |