Trane 2TWB3018-060 manual General Data, Product Specifications, A-weightedSound Power Level dBA

Models: 2TWB3018-060

1 10
Download 10 pages 18.72 Kb
Page 4
Image 4
General

General

Data

Product Specifications

Model No. 1

 

2TWB3018A1

2TWB3024A1

2TWB3030A1

2TWB3036A1

Electrical Data V/Ph/Hz 2

200/230/1/60

200/230/1/60

200/230/1/60

200/230/1/60

Min Cir Ampacity

 

8

12

13

19

Max Fuse Size (Amps)

15

20

20

30

Compressor

 

CLIMATUFF ®

CLIMATUFF®

CLIMATUFF®

CLIMATUFF®

RL Amps - LR Amps

 

5.9 - 38.6

8.7 - 57.8

9.5 - 63

14.1 - 90.8

Outdoor Fan FL Amps

 

0.6

1.3

0.9

1.4

Fan HP

 

1/15

1/4

1/8

1/6

Fan Dia (inches)

 

19.0

19.0

23.0

27.6

Coil

 

Spine Fin™

Spine Fin™

Spine Fin™

Spine Fin™

Refrigerant R-22 (Not Factory Supplied) 5/10-LB/OZ

5/11-LB/OZ

6/07-LB/OZ

7/06-LB/OZ

Line Size - (in.) O.D. Gas 3

5/8

3/4

3/4

7/8

Line Size - (in.) O.D. Liquid 3

1/4

5/16

5/16

3/8

Dimensions H x W x D (Crated)

37.2 x 26.7 x 30

37.2 x 26.7 x 30

42 x 30.1 x 33

42.4 x 35.1 x 38.7

Weight - Shipping

 

202

205

240

291

Weight - Net

 

182

184

212

256

Start Components

 

YES

YES

YES

YES

Sound Enclosure

 

NO

NO

NO

YES

Compressor Sump Heat

YES

YES

YES

YES

Optional Accessories: 4

 

 

 

 

Anti-short Cycle Timer

 

TAYASCT501A

TAYASCT501A

TAYASCT501A

TAYASCT501A

Evaporator Defrost Control A/C

AY28X084

AY28X084

AY28X084

AY28X084

Rubber Isolator Kit

 

BAYISLT101

BAYISLT101

BAYISLT101

BAYISLT101

Snow Leg-Base & Cap 4" High

BAYLEGS002

BAYLEGS002

BAYLEGS002

BAYLEGS002

Snow Leg-4" Extension

BAYLEGS003

BAYLEGS003

BAYLEGS003

BAYLEGS003

Extreme Condition

Mounting

KitBAYECMT023

BAYECMT023

BAYECMT023

BAYECMT004

Refrigerant Lineset

5

TAYREFLN1*

TAYREFLN2*

TAYREFLN2*

TAYREFLN3*

 

 

 

 

 

 

1Certified in accordance with the Air-Source Unitary Heat Pump equipment certification program which is based on AHRI Standard 210/240.

2 Calculated in accordance with N.E.C. Use only HACR circuit breakers or fuses.

3 Standard line lengths - 60', Standard lift - 60' Suction and Liquid line.

For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0. (denotes latest revision)

4 For accessory description and usage, see page 5. 5 * = 15, 20, 25, 30, 40 and 50 foot lineset available.

A-weighted Sound Power Level [dB(A)]

 

SOUND POWER

A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB - [dB(A)]

MODEL

LEVEL [dB(A)]

63

125

250

500

1000

2000

4000

8000

 

 

 

 

 

 

 

 

 

 

2TWB3018A1

74

43.5

52.1

57.0

65.5

67.3

66.8

62.1

55.4

 

 

 

 

 

 

 

 

 

 

2TWB3024A1

79

51.3

56.1

61.7

71.5

73.1

71.8

64.3

55.8

 

 

 

 

 

 

 

 

 

 

2TWB3030A1

79

43.8

58.8

62.2

69.2

72.1

71.4

62.5

56.8

 

 

 

 

 

 

 

 

 

 

2TWB3036A1

79

47.1

60.4

67.8

73.5

73.7

71.6

63.8

51.4

 

 

 

 

 

 

 

 

 

 

2TWB3042A1

80

48.6

59.9

66.9

73.0

75.2

70.3

64.4

55.2

 

 

 

 

 

 

 

 

 

 

2TWB3048A1

78

45.4

58.8

66.1

72.5

72.5

69.8

63.0

52.5

 

 

 

 

 

 

 

 

 

 

2TWB3060A1

79

46.7

55.2

66.5

73.5

73.8

71.8

65.8

56.7

 

 

 

 

 

 

 

 

 

 

Note: Tested in accordance with AHRI Standard 270.95. (Not listed with AHRI)

4

22-1771-04

Page 4
Image 4
Trane 2TWB3018-060 manual General Data, Product Specifications, A-weightedSound Power Level dBA