General

General

Data

Product Specifications 1

MODEL

TUD040C924K

TUD040C930K

TUD060C924K

TUD060C936K

TYPE

 

Upflow / Horizontal

Upflow / Horizontal

Upflow / Horizontal

Upflow / Horizontal

RATINGS 2

 

 

 

 

Input BTUH

40,000

40,000

60,000

60,000

Capacity BTUH (ICS) 3

32,000

32,000

47,000

47,000

AFUE

 

80.0

80.0

80.0

80.0

Temp. rise (Min.-Max.) °F.

30 - 60

30 - 60

35 - 65

30 - 60

BLOWER DRIVE

DIRECT

DIRECT

DIRECT

DIRECT

Diameter - Width (In.)

10 x 6

10 x 6

10 x 6

10 x 7

No. Used

1

1

1

1

Speeds (No.)

4

4

4

4

CFM vs. in. w.g.

See Fan Performance Table

See Fan Performance Table

See Fan Performance Table

See Fan Performance Table

Motor HP

1/5

1/3

1/5

1/3

R.P.M.

 

1080

1075

1080

1075

Volts / Ph / Hz

115/1/60

115/1/60

115/1/60

115/1/60

COMBUSTION FAN - Type

Centrifugal

Centrifugal

Centrifugal

Centrifugal

Drive -

No. Speeds

Direct - 1

Direct - 1

Direct - 1

Direct - 1

Motor HP - RPM

1/50 - 3000

1/50 - 3000

1/50 - 3000

1/50 - 3000

Volts / Ph / Hz

115/1/60

115/1/60

115/1/60

115/1/60

FLA

 

1.0

1.0

1.0

1.0

FILTER — Furnished?

Yes

Yes

Yes

Yes

Type Recommended

High Velocity

High Velocity

High Velocity

High Velocity

Hi Vel. (No.-Size-Thk.)

1 - 17x25 - 1in.

1 - 17x25 - 1in.

1 - 17x25 - 1in.

1 - 17x25 - 1in.

VENT — Size (in.)

4 Round

4 Round

4 Round

4 Round

HEAT EXCHANGER

 

 

 

 

Type

-Fired

Aluminized Steel - Type I

Aluminized Steel - Type I

Aluminized Steel - Type I

Aluminized Steel - Type I

 

-Unfired

 

 

 

 

Gauge (Fired)

20

20

20

20

ORIFICES — Main

 

 

 

 

Nat. Gas. Qty. — Drill Size

2 — 45

2 — 45

3 — 45

3 — 45

L.P. Gas Qty. — Drill Size

2 — 56

2 — 56

3 — 56

3 — 56

GAS VALVE

Redundant - Single Stage

Redundant - Single Stage

Redundant - Single Stage

Redundant - Single Stage

PILOT SAFETY DEVICE

 

 

 

 

Type

 

Hot Surface Ignition

Hot Surface Ignition

Hot Surface Ignition

Hot Surface Ignition

BURNERS — Type

Multi-port In-shot

Multi-port In-shot

Multi-port In-shot

Multi-port In-shot

Number

2

2

3

3

POWER CONN. — V / Ph / Hz 4

115/1/60

115/1/60

115/1/60

115/1/60

Ampacity (In Amps)

6.3

6.3

10.4

10.4

Max. Overcurrent Protection (Amps)

15

15

15

15

PIPE CONN. SIZE (IN.)

1/2

1/2

1/2

1/2

DIMENSIONS

H x W x D

H x W x D

H x W x D

H x W x D

Crated (In.)

41-3/4 x 16-1/2 x 30-1/2

41-3/4 x 16-1/2 x 30-1/2

41-3/4 x 16-1/2 x 30-1/2

41-3/4 x 16-1/2 x 30-1/2

WEIGHT

 

 

 

 

Shipping (Lbs.) / Net (Lbs)

119 / 110

122 / 113

124 / 115

127 / 118

1Central Furnace heating designs are certified by AGA and CSA.

2For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.

3Based on U.S. government standard tests.

4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.