Transition Networks AR-CF-02 Fiber Cable, Coax Cable/Star Topology, Coax Cable/Bus Topology

Models: AR-CF-02 AR-CF-02(SC) AR-CF-02(SM)

1 2
Download 2 pages 41.54 Kb
Page 2
Image 2
Installation NOTES

Installation NOTES

CABLE SPECIFICATIONS

AR-CF-02

Install Coax Copper

STAR TOPOLOGY

MAXIMUM coax segment to active hub is 600 meters (2000 feet) on RG-62 cable; minimum does not apply.

BUS TOPOLOGY

Devices attached to coax bus must be located AT LEAST six

(6) feet apart.

MAXIMUM coax bus length is 300 meters (1000 feet); minimum is 1.8 meters (6 feet).

Device(s) attached to EACH END of bus must be terminated. NOTE: If the media converter is installed at one end of the bus, use the configuration switch to terminate the media converter.

CONFIGURATION SWITCH

NOTE: Set configuration switch (located on the side of media converter) according to site installation requirements:

Switch 1

NOT USED

 

Switch 2

UP = OFF

Media converter TRANSFERS signal

 

DOWN = ON

Media converter TERMINATES signal.

Install Fiber

Connect one end of first fiber cable to AR-CF-02 media converter TX connector.

Connect other end of that fiber cable to second AR-CF-02 media converter RX connector.

Connect one end of second fiber cable to AR-CF-02 media converter RX connector.

Connect other end of that fiber cable to AR-CF-02 media converter TX connector.

Power

Locate correct power supply adapter for site installation.

Connect media converter power connector at end of power supply adapter cord to AR-CF-02 media converter power receptacle.

Connect 2-prong or 3-prong external power connector on other end of power supply adapter cord to external AC power.

The physical characteristics of the cable must meet or exceed the following:

FIBER CABLE

MULTIMODE

 

 

Fiber Optic Cable Recommended:

62.5 / 125 µm multimode fiber

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -32.5 dBm

max: -14.0 dBm

Wavelength:

850nM

 

Bit error rate:

10-9

 

Maximum Cable Distance:

2 kilometers

 

SINGLEMODE

 

 

Fiber Optic Cable Recommended:

9 µm singlemode fiber

Fiber Optic Transmitter Power:

min: -27.0 dBm

max: -17.0 dBm

Fiber Optic Receiver Sensitivity:

min: -32.5 dBm

max: -13.0 dBm

Wavelength:

1300nM

 

Bit error rate:

10-9

 

Maximum Cable Distance:

8 kilometers

 

COAX CABLE/STAR TOPOLOGY

RG-62 Cable

 

Cable Characteristics:

 

Cable type:

Coaxial RG-62/u

Impedance:

75 Ω @ 10 MHz

Mutual Capacitance:

13 pF/ft ±20% @ 10 MHz

Maximum Attenuation:

5.5 dB/1000 feet

Maximum Cable Distance:

600 meters (2000 feet)

Minimum Distance/Connection:

0 meters (0 feet)

RG-59 Cable

 

Cable Characteristics:

 

Cable type:

Coaxial RG-59/u

Impedance:

93 Ω @ 10 MHz

Mutual Capacitance:

13 pF/ft ±20% @ 10 MHz

Maximum Attenuation:

7.0 dB/1000 feet

Maximum Cable Distance:

450 meters (1500 feet)

Minimum Distance/Connection:

0 meters (0 feet)

COAX CABLE/BUS TOPOLOGY

RG-62 Cable

 

Cable Characteristics:

 

Cable type:

Coaxial RG-62/u

Impedance:

93 Ω @ 10 MHz

Mutual Capacitance:

13 pF/ft ±20% @ 10 MHz

Maximum Attenuation:

5.5 dB/1000 feet

Maximum Cable Distance:

300 meters (1000 feet)

Minimum Distance/Connection:

1.8 meters (6 feet)

Page 2
Image 2
Transition Networks AR-CF-02 Fiber Cable, Coax Cable/Star Topology, Coax Cable/Bus Topology, Installation NOTES, Power