Installation NOTES
CABLE SPECIFICATIONS
AR-CF-02
Install Coax Copper
STAR TOPOLOGY
•MAXIMUM coax segment to active hub is 600 meters (2000 feet) on
BUS TOPOLOGY
•Devices attached to coax bus must be located AT LEAST six
(6) feet apart.
•MAXIMUM coax bus length is 300 meters (1000 feet); minimum is 1.8 meters (6 feet).
•Device(s) attached to EACH END of bus must be terminated. NOTE: If the media converter is installed at one end of the bus, use the configuration switch to terminate the media converter.
CONFIGURATION SWITCH
NOTE: Set configuration switch (located on the side of media converter) according to site installation requirements:
Switch 1 | NOT USED |
|
Switch 2 | UP = OFF | Media converter TRANSFERS signal |
| DOWN = ON | Media converter TERMINATES signal. |
Install Fiber
•Connect one end of first fiber cable to
•Connect other end of that fiber cable to second
•Connect one end of second fiber cable to
•Connect other end of that fiber cable to
Power
•Locate correct power supply adapter for site installation.
•Connect media converter power connector at end of power supply adapter cord to
•Connect
The physical characteristics of the cable must meet or exceed the following:
FIBER CABLE
MULTIMODE |
|
|
Fiber Optic Cable Recommended: | 62.5 / 125 µm multimode fiber | |
Fiber Optic Transmitter Power: | min: | max: |
Fiber Optic Receiver Sensitivity: | min: | max: |
Wavelength: | 850nM |
|
Bit error rate: | ≤ |
|
Maximum Cable Distance: | 2 kilometers |
|
SINGLEMODE |
|
|
Fiber Optic Cable Recommended: | 9 µm singlemode fiber | |
Fiber Optic Transmitter Power: | min: | max: |
Fiber Optic Receiver Sensitivity: | min: | max: |
Wavelength: | 1300nM |
|
Bit error rate: | ≤ |
|
Maximum Cable Distance: | 8 kilometers |
|
COAX CABLE/STAR TOPOLOGY
|
|
Cable Characteristics: |
|
Cable type: | Coaxial |
Impedance: | 75 Ω @ 10 MHz |
Mutual Capacitance: | 13 pF/ft ±20% @ 10 MHz |
Maximum Attenuation: | 5.5 dB/1000 feet |
Maximum Cable Distance: | 600 meters (2000 feet) |
Minimum Distance/Connection: | 0 meters (0 feet) |
|
|
Cable Characteristics: |
|
Cable type: | Coaxial |
Impedance: | 93 Ω @ 10 MHz |
Mutual Capacitance: | 13 pF/ft ±20% @ 10 MHz |
Maximum Attenuation: | 7.0 dB/1000 feet |
Maximum Cable Distance: | 450 meters (1500 feet) |
Minimum Distance/Connection: | 0 meters (0 feet) |
COAX CABLE/BUS TOPOLOGY
| |
Cable Characteristics: |
|
Cable type: | Coaxial |
Impedance: | 93 Ω @ 10 MHz |
Mutual Capacitance: | 13 pF/ft ±20% @ 10 MHz |
Maximum Attenuation: | 5.5 dB/1000 feet |
Maximum Cable Distance: | 300 meters (1000 feet) |
Minimum Distance/Connection: | 1.8 meters (6 feet) |