CPSMC0100-210

Installation -- Continued

Grounding the Media Converter

The CPSMC0100-210 single-slot chassis comes equipped with grounding lugs located on the back panel. They require a grounding conductor wire terminated with a two-hole, compression-type, grounding connector. The grounding wire -- which must be a copper conductor -- is not included with the chassis and must be provided by the customer/installer.

The electrical conducting path from the single-slot chassis must:

Flow via the grounding lugs to the common bonding network (CBN) for telecom installations, or to an alternative approved grounding system (if required) for non-telecom installations.

Be of sufficiently low impedance to conduct fault currents likely to be imposed on the media converter, and

Enable proper operation of any over-current protection devices.

The conductor must be fastened to the grounding lugs with the enclosed anti- rotation star-washers and lug-nut fasteners. The applied torque required to the connector lug-nut fasteners is specified by the connector’s manufacturer.

Lug nuts (included)

Star washer (included)

Two-hole, compression-type grounding connector

(not included)

Grounding lugs

12 AWG copper wire

(6-32, 1/8" diam.)

(not included)

3/4-inch

spacing

To properly ground the CPSMC0100-210 single-slot chassis:

1.Obtain one (1) grounding conductor (12 AWG copper wire gauge or larger) with a two-hole, compression-type, grounding connector.

2.Attach the grounding conductor to the converter by placing the two-hole connector onto the grounding lugs and fasten with the enclosed lock- washers / lug-nuts at the proper torque (per the manufacturer’s specification).

Technical Specifications

For use with Transition Networks Model CPSMC0100-210 or equivalent.

Note: The maximum power delivery capacity for the chassis slot is 12 Watts.

Compliance

EN55022; CISPR 22; Class A & B; CE Mark

Dimensions

6.086 x 5.875 x 1.5 in (155 x 149 x 38 mm)

Weight

1.6 lbs. (0.7 kg) Approximately

Power Supply

12VDC, 1.25 A (maximum)

MTBF

49,888 hours (MIL217F2 V5.0) (MIL-HDBK-217F)

 

133,257 hours (Bellcore7 V5.0)

Environment

Tmra*:

0 to 50°C (32 to 122° F )

 

Storage Temp:

-20 to 85°C

 

Humidity:

5 to 95%, non condensing

 

Altitude:

0 to 10,000 feet

Warranty

Lifetime

 

*Manufacturer’s rated ambient temperature.

The information contained in this user’s guide is subject to change. For the most up-to-date information on the CPSMC0100-210 single-slot chassis, view the user’s guide on-line at: www.transition.com.

3. Attach the opposite end of the grounding conductor to the common bonding network (CBN) for telecom, or to earth ground (if required) for non- telecom installations.

grounding lugs

grounding connector and wire

earth ground

424-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600

techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.

5

Page 3
Image 3
Transition Networks CPSMC0100-210 technical specifications Technical Specifications, Grounding the Media Converter