Transition Networks DVP 5960 Installation NOTES, Cable Specifications, Fiber Cable, PS-CF-01

Models: DVP 5960

1 4
Download 4 pages 9.85 Kb
Page 2
Image 2
Installation NOTES

Installation NOTES

CABLE SPECIFICATIONS

PS-CF-01

All cable connections to the PS-CF-01 MUST be

AT LEAST 7.6 meters (25 feet) in length.

To install the PS-CF-01 series media converter:

1. Connect host signal to PS-CF-01 media converter.

Locate or build twisted-pair cables that are compliant with cable specifications (See page 7) and with male RJ-45 plug connectors installed at both cable ends.

NOTE: Install TRANSITION Networks balun part number: 3-4554 between RJ-45 cable and Twinax connector.

Install balun at host Twinax connector.

•.Connect male RJ-45 plug connector at one end of twisted pair cable to balun on host Twinax connector.

• Connect male RJ-45 plug connector at other end of twisted

pair cable to female RJ-45 connector on PS-CF-01 media

converter.

2. Connect PS-CF-01 media converter near host to second PS-CF-01

media converter near terminal device*.

• Locate or build fiber cable that conforms to cable

specifications (See page 7) and with male fiber connectors

installed at both ends.

• Connect one end of first fiber cable to PS-CF-01 media

converter TX connector.

• Connect other end of that fiber cable to second PS-CF-01

media converter RX connector (or to PowerStar™ IV fiber SIC

card RX connector).

The physical characteristics of the cable must meet or exceed the following:

FIBER CABLE

MULTIMODE

 

 

Fiber Optic Cable Recommended:

62.5 / 125 µm multimode fiber

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -32.5 dBm

max: -14.0 dBm

Wavelength:

850nM

 

Bit error rate:

10-9

 

Maximum Cable Distance:

2 kilometers

 

SINGLEMODE

 

 

Fiber Optic Cable Recommended:

9 µm singlemode fiber

Fiber Optic Transmitter Power:

min: -27.0 dBm

max: -17.0 dBm

Fiber Optic Receiver Sensitivity:

min: -32.5 dBm

max: -13.0 dBm

Wavelength:

1300nM

 

Bit error rate:

10-9

 

Maximum Cable Distance:

8 kilometers

 

TWISTED PAIR CABLE AND CONNECTOR

Category 3 wire or better is required; category 5 wire is recommended. Either shielded twisted pair (STP) or unshielded twisted pair (UTP) can be used. DO NOT USE FLAT OR SILVER SATIN WIRE.

Category 3:

 

Gauge

24 to 22 AWG

Attenuation

28 dB/1000’ @ 10 MHz

Differential Characteristic Impedance

100 ±10% @ 10 MHz

Category 5:

 

Gauge

24 to 22 AWG

Attenuation

20 dB/1000’ @ 10 MHz

Differential Characteristic Impedance

100 ±10% @ 10 MHz

Minimum UTP/STP Cable Distance:

7.6 meters (25 feet)

Maximum UTP/STP Cable Distance:

762 meters (2500 feet)

Connector:

RJ-45 connectors with active

 

pair pins 4 & 5.

Connect one end of second fiber cable to PS-CF-01 media

 

converter RX connector.

Connect other end of that fiber cable to second PS-CF-01

 

media converter TX connector (or to PowerStar™ IV fiber SIC

 

card TX connector).

*Or optionally connect directly to PowerStar™ IV fiber SIC card.

NOTE: The active pair in a twisted-pair copper 5250-compliant network are pins 4 & 5. Use only dedicated wire pairs (such as blue/white & white/blue, orange/white & white/orange) for the active pins.

Straight Through Cable

3

3

4

 

4

 

RJ-45

 

RJ-45

connector

 

connector

55

66

2

7

Page 2
Image 2
Transition Networks DVP 5960 Installation NOTES, Cable Specifications, Fiber Cable, Twisted Pair Cable And Connector