Transition Networks E-TBT-MC04 Cable Specifications, Troubleshooting, Contact Us, Copper cables

Models: E-TBT-MC04

1 7
Download 7 pages 8.32 Kb
Page 6
Image 6
Cable Specifications

E-TBT-MC04

Cable Specifications

The physical characteristics of the media cable must meet or exceed IEEE 802.3 specifications.

Copper cables

Category 3: (minimum requirement)

 

Gauge

24 to 22 AWG

Attenuation

11.5 dB/100m @ 5-10 MHz

Maximum cable distance:

100 m

Category 5: (recommended)

 

Gauge

24 to 22 AWG

Attenuation

22.0 dB/100m @ 100 MHz

Maximum cable distance:

100 m

Straight-through or crossover twisted-pair cable may be used.

Shielded (STP) or unshielded (UTP) twisted-pair cable may be used.

Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .

RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-

Use only dedicated wire pairs for the active pins:

(e.g., blue/white & white/blue, orange/white & white/orange, etc.)

Do not use flat or silver satin wire.

Troubleshooting

If the transceiver fails, determine the answer to the following questions:

1.Is the status LED flashing?

NO

Verify that the AUI device is turned ON.

Verify that the AUI cable from the transceiver to the AUI device port is installed properly.

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

YES

Go to step 2.

2.Is the RX LED flashing (receiving data)?

NO

Is the LED ON Solid?

Check twisted pair cable for proper connection

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

Yes

Go to step 3.

3.Is the TX LED ON?

NO

Check twisted pair cable for proper connection.

Is the LED flashing (transmitting data)?

Restart the hardware to force re-initialization.

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

Yes

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

E-TBT-MC04

Contact Us

Technical support

Technical support is available 24 hours a day.

US and Canada:

1-800-260-1312

International:

00-1-952-941-7600

Transition now

Chat live via the Web with Transition Networks Technical Support. Log onto www.transition.com and click the Transition Now link.

Web-based seminars

Transition Networks provides seminars via live web-based training. Log onto www.transition.com and click the Learning Center link.

E-Mail

Ask a question anytime by sending an e-mail to our technical support staff at techsupport@transition.com

Address

Transition Networks: 10900 Red Circle Drive, Minnetonka MN 55343, U.S.A.

telephone: 952-941-7600; toll free: 800-526-9267; fax: 952-941-2322

 

Declaration of Conformity

Name of Mfg:

Transition Networks

 

10900 Red Circle Drive, Minnetonka MN 55343 U.S.A.

Model:

E-TBT-MC04 Transceiver

Part Number(s):

E-TBT-MC04

Regulation:

EMC Directive 89/336/EEC

Purpose: To declare that the E-TBT-MC04 Transceiver to which this declaration refers is in conformity with the following standards.

EN55022:1998 + A1:2000 + A1:2003 EN 55024:1998 + A1:2000 + A2:2003

I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).

 

August, 2008_____

Stephen Anderson, Vice-President of Engineering

Date

10

24-Hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600

techsupport@transition.com -- Click the “Transition Now” link for live Web chat.

11

Page 6
Image 6
Transition Networks E-TBT-MC04 Cable Specifications, Troubleshooting, Contact Us, Copper cables, Category 5 recommended