Transition Networks SGETF1014-100 Operation, FAULT ISOLATION and CORRECTION, Using Status LEDs

Models: SGETF1025-100 SGETF1013-100 SGETF1018-100 SGETF1015-100 SGETF1014-100 SGETF1017-100

1 4
Download 4 pages 57.5 Kb
Page 4
Image 4
OPERATION

OPERATION

Using Status LEDs

Use the status LEDs to monitor media converter operation in the network.

FAULT ISOLATION and CORRECTION

If the media converter fails, isolate and correct the fault by determining the answers to the following questions and then taking the indicated action:

P(o)W(e)R

Steady LED indicates connection to

 

external AC power.

RXF

(Fiber receive) Flashing LED

 

indicates reception of data on fiber

 

link.

LKF

(Fiber link) Steady LED indicates

 

fiber link connection.

Using Status LEDs PWR

RXF FAULT ISOLATION and CORRECTIONManual background LKF

RXC Manual backgroundManual background LKC

1.Is the P(o)W(e)R LED on the media converter illuminated?

NO

Is the power cord properly installed in the media converter and at the external power source?

Does the external power source provide power?

Contact Technical Support: (800) 260-1312.

YES

 

• Proceed to step 2.

2.

Is the LKC LED on the media converter illuminated?

RXC

(Copper receive) Flashing LED indicates reception of data on

 

copper link.

LKC

(Copper link) Steady LED indicates copper link connection.

NO

• Check twisted-pair cables for proper connection.

Check twisted-pair cables for connection of all four pairs.

Contact Technical Support: (800) 260-1312.

YES

Proceed to step 3.

3.Is the LKF LED on the media converter illuminated?

NO

Check fiber cables for proper connection.

Verify that TX and RX cables on media converter are connected to RX and TX ports, respectively, on other device.

Contact Technical Support: (800) 260-1312.

YES

Proceed to step 4.

4.Is the RXC LED on the media converter flashing?

NO

If there is NO ACTIVITY on the 1000BASE-TX port, proceed to step 5.

If there is ACTIVITY on the 1000BASE-TX port, disconnect and reconnect the 1000BASE-TX cable to restart the initialization process.

Restart the workstation to restart the initialization process.

Contact Technical Support: (800) 260-1312.

YES

Proceed to step 5.

5.Is the RXF LED on the media converter flashing?

NO

If there is NO ACTIVITY on the 1000BASE-SX/LX port, continue below

If there is ACTIVITY on the 1000BASE-SX/LX port, disconnect and reconnect the fiber cable to restart the initialization process.

Restart the workstation to restart the initialization process.

Contact Technical Support: (800) 260-1312.

YES

Contact Technical Support: (800) 260-1312.

Page 4
Image 4
Transition Networks SGETF1014-100, SGETF1018-100 Operation, FAULT ISOLATION and CORRECTION, Using Status LEDs