Transition Networks SISTF10xx-130-LR(T) Cable Specifications, Copper Cable, Fiber Cable

Models: SISTF10xx-130-LR(T)

1 9
Download 9 pages 30.62 Kb
Page 6
Image 6

SISTF10xx-130-LR(T)

Cable Specifications -- Continued

Copper Cable

Category 5: (minimum requirement)

 

Gauge:

24 to 22 AWG

Attenuation:

22.0 dB /100m @ 100 MHz

Maximum Cable Distance:

100 meters

Straight-through OR crossover cable may be used.

Shielded twisted-pair (STP) OR unshielded twisted-pair (UTP) may be used

Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .

RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-

Use only dedicated wire pairs for the active pins:

(e.g., blue/white & white/blue, orange/white & white/orange, etc.)

Do not use flat or silver satin wire.

 

Straight-Through Cable

 

Crossover Cable

 

Twisted Pair #1

 

 

1

 

 

1

 

Twisted Pair #1

1

 

 

1

 

 

2

 

 

2

 

2

 

 

2

 

 

 

 

 

 

 

 

 

Twisted Pair #2

 

 

3

 

3

 

Twisted Pair #2

3

 

 

3

 

 

 

 

 

 

 

6

 

 

6

 

6

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Please note the following when wiring the network:

Signal lines must not be directly connected to outdoor wiring.

Use separate paths to route the power wiring and the signal wiring. If power wiring and signal wiring paths must cross, make sure the wires are perpendicular at the intersection point.

Do not run signal wiring and power wiring in the same wire conduit. To avoid interference, wires with different signal characteristics should also be routed separately.

Use the type of signal transmitted through a wire to determine which wires should be kept separate. The rule of thumb is that wiring with similar electrical characteristics can be bundled together.

Keep input wiring and output wiring separate.

Where necessary, label the wiring to all devices in the network.

NOTE: This device has been evaluated as EEx nC IIC T4 equipment under DEMKO Certificate No. 03 ATEX 0324537U. Each module is suitable for use in Zone 2 Explosive Atmospheres. The device must be installed in a minimum IP 54 enclosure as defined in IEC 60529 and EN 60529.

NOTE: This unit is a building-in type. The installation into a certain end equipment shall comply with fire enclosure request of IEC 60950/EN60950 or similar sentence.

Cable Specifications

The physical characteristics must meet or exceed IEEE 802.3™ specifications.

Fiber Cable

Bit Error Rate:

<10-9

 

Single mode fiber (recommended):

9 µm

 

Multimode fiber (recommended):

62.5/125 µm

 

Multimode fiber (optional):

100/140, 85/140, 50/125 µm

Standard Models

 

 

SISTF1011-130-LR

1300 nm multimode

Fiber Optic Transmitter Power:

min: -20.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -36.0 dBm

max: -32.0 dBm

Link Budget:

16.0 dB

 

SISTF1012-130-LR

1310 nm single mode

Fiber Optic Transmitter Power:

min: -15.0 dBm

max: -6.0 dBm

Fiber Optic Receiver Sensitivity:

min: -34.0 dBm

max: -32.0 dBm

Link Budget:

19.0 dB

 

SISTF1013-130-LR

1300 nm multimode

Fiber Optic Transmitter Power:

min: -20.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -36.0 dBm

max: -32.0 dBm

Link Budget:

16.0 dB

 

SISTF1014-130-LR

1310 nm single mode

Fiber Optic Transmitter Power:

min: -15.0 dBm

max: -6.0 dBm

Fiber Optic Receiver Sensitivity:

min: -34.0 dBm

max: -32.0 dBm

Link Budget:

19.0 dB

 

Extended Temperature Models

 

 

SISTF1011-130-LRT

1300 nm multimode

Fiber Optic Transmitter Power:

min: -20.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -36.0 dBm

max: -32.0 dBm

Link Budget:

16.0 dB

 

SISTF1012-130-LRT

1310 nm single mode

Fiber Optic Transmitter Power:

min: -15.0 dBm

max: -6.0 dBm

Fiber Optic Receiver Sensitivity:

min: -34.0 dBm

max: -32.0 dBm

Link Budget:

19.0 dB

 

SISTF1013-130-LRT

1300 nm multimode

Fiber Optic Transmitter Power:

min: -20.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -36.0 dBm

max: -32.0 dBm

Link Budget:

16.0 dB

 

SISTF1014-130-LRT

1310 nm single mode

Fiber Optic Transmitter Power:

min: -15.0 dBm

max: -6.0 dBm

Fiber Optic Receiver Sensitivity:

min: -34.0 dBm

max: -32.0 dBm

Link Budget:

19.0 dB

 

NOTE: The fiber optic transmitters on this device meet Class I Laser safety requirements per IEC-825/CDRH standards and comply with 21 CFR1040.10 and 21CFR1040.11.

10

24-hour Technical Support: 1-800-260-1312-- International: 00-1-952-941-7600