Technical Specifications
For use with Transition Networks Model
Standards: IEEE 802.3™, 802.3u™; 802.3x™
Data Rate: 10 Mb/s, 100 Mb/s (copper); 100 Mb/s (fiber)
Processing Type: Store and Forward
w/ IEEE802.3x™
Dimensions: 1.8" x 5.3" x 4.1" (46 mm x 135 mm x 105 mm)
Weight:1.4 lb. (0.65 kg) (approximate)
Input Power:
Address Table Size: 1,000 Unicast Mac addresses
Alarm Relay: 1 Amp @ 24 VDC
Mechanical: Ingress Protection: IP30
Environment: Tmra* (standard temp): 0 to 60°C (32 to 140°F) Tmra* (extended temp):
| Storage Temperature: | |
| Humidity: | 5 to 95%, non condensing |
Warranty: | Lifetime |
|
*Manufacturer’s rated ambient temperature.
The information contained in this user’s guide is subject to change. For the most
CAUTION: This device is intended to be supplied by a listed power unit marked LPS or Limited Power Source, provided with a connector for field wiring terminal, and output rated
CAUTION: This device is designed for operation with a safety
This device is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the date of manufacture.
CAUTION: Visible and invisible laser radiation when open. Do not stare into beam or view directly with optical instruments.
CAUTION: Use of controls, adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure
Technical Specifications
EMS Type Tests
Test | Description |
| Test Levels | Severity |
|
|
|
|
|
ESD | Air discharge | +/- 8 KV | 3 | |
|
| Contact discharge | +/- 6 KV | 3 |
|
|
|
|
|
|
| ESD contact discharge | +/- 6 KV | 3 |
|
|
|
|
|
Radiated RFI | Housing | 10V/m, 80 MHz - 1 GHz | 3 | |
|
|
| AM 1 KHz, 80% mod |
|
|
|
| 10 V/m, 0.9 - 1.8 GHz |
|
|
|
| FM 200 Hz 50% square |
|
|
|
|
|
|
Burst | Power supply lines | +/- 2 KV | 3 | |
| (Fast Transient) |
|
|
|
| Communication lines | +/- 1 KV | 3 | |
|
| Relay | +/- 1 KV | 3 |
|
|
|
|
|
Surge | Power supply lines | +/- 2 KV, 12 Ω, CM | 3 | |
|
|
| +/- 1 KV, 2 Ω, DM |
|
|
|
|
|
|
|
| Relay | +/- 2 KV, 12 Ω, CM | 3 |
|
|
| +/- 1 KV, 2 Ω, DM |
|
|
|
|
|
|
Induced | Power supply lines | 10 Vrms, | 3 | |
| (Conducted RFI) |
| AM 1 KHz, 80% mod |
|
|
|
|
|
|
|
| Communication lines | 10 Vrms, | 3 |
|
|
| AM 1 KHz, 80% mod |
|
|
|
|
|
|
|
| Relay | 10 Vrms, | 3 |
|
|
| AM 1 KHz, 80% mod |
|
|
|
|
|
|
Environmental Type Tests
Test | Description | Test Levels |
|
|
|
IEC | Vibration | 10 - 500 - 10 Hz, 0.5 oct./min, 4g, X, Y, Z (3 axes) |
IEC | Shock | 50 g, 11 ms, |
|
|
|
IEC | Free fall | 75 cm, 1 corner, 3 edges, 6 faces (total 10 drops) |
|
|
|