SSEFE10xx-10x

Cable Specifications

The physical characteristics must meet or exceed IEEE 802.3™ specifications.

Cable Specifications -- Continued

Copper Cable

Fiber Cable

Bit Error Rate:

Single mode:

SSEFE1012-100

Fiber-optic Transmitter Power:

Fiber-optic Receiver Sensitivity:

Link Budget:

SSEFE1014-100

Fiber-optic Transmitter Power:

Fiber-optic Receiver Sensitivity:

Link Budget:

SSEFE1015-100

Fiber Optic Transmitter Power:

Fiber Optic Receiver Sensitivity:

Link Budget:

SSEFE1022-100

Fiber Optic Transmitter Power:

Fiber Optic Receiver Sensitivity:

Link Budget:

SSEFE1029-100

Fiber-optic Transmitter Power:

Fiber-optic Receiver Sensitivity:

Link Budget:

SSEFE1029-101

Fiber-optic Transmitter Power:

Fiber-optic Receiver Sensitivity:

Link Budget:

<10-99 µm

1310 nm single mode

min: -15.0 dBm

max: -8.0 dBm

min: -32.0 dBm

max: -5.0 dBm

17.0 dB

 

1310 nm single mode

min: -15.0 dBm

max: -8.0 dBm

min: -32.0 dBm

max: -5.0 dBm

17.0 dB

 

1310 nm single mode

min: -8.0 dBm

max: -2.0 dBm

min: -34.0 dBm

max: -5.0 dBm

26.0 dB

 

1310 nm single mode

min: -8.0 dBm

max: -2.0 dBm

min: -34.0 dBm

max: -5.0 dBm

26.0 dB

 

1310 nm (TX)/1550 nm (RX) simplex

min: -14.0 dBm

max: -8.0 dBm

min: -33.0 dBm

max: -3.0 dBm

19.0 dB

 

1550 nm (TX)/1310 nm (RX) simplex

min: -14.0 dBm

max: -8.0 dBm

min: -33.0 dBm

max: -3.0 dBm

19.0 dB

 

Category 3: (Minimum requirement for 10 Mb/s operation)

Gauge

24 to 22 AWG

Attenuation

11.5 dB/100m @ 5-10 MHz

Category 5: (Minimum requirement for 100 Mb/s operation)

Gauge

24 to 22 AWG

Attenuation

22.0 dB /100m @ 100 MHz

Straight-through or crossover copper cable may be used.

Shielded (STP) or unshielded (UTP) twisted-pair cable may be used.

Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .

RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-

Use only dedicated wire pairs for the active pins:

(e.g., blue/white & white/blue, orange/white & white/orange, etc.)

Do not use flat or silver satin wire.

 

Straight-Through Cable

 

Crossover Cable

 

 

Twisted Pair #1

 

 

1

 

 

1

 

Twisted Pair #1

1

 

 

1

 

 

 

2

 

 

 

2

 

2

 

 

2

 

 

 

 

 

 

 

 

 

 

Twisted Pair #2

 

 

3

 

 

3

 

Twisted Pair #2

3

 

 

3

 

 

 

 

 

 

 

 

 

6

 

 

 

6

 

6

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The fiber optic transmitters on this device meet Class I Laser safety requirements per IEC-825/CDRH standards and comply with 21 CFR1040.10 and 21CFR1040.11.

6

24-Hour Technical Support: 1-800-260-1312-- International: 00-1-952-941-7600

techsupport@transition.com -- Click the “Transition Now” link for a live Web chat

7

Page 4
Image 4
Transition Networks SSEFE10XX-10X specifications Cable Specifications, Copper Cable Fiber Cable