Specifications

Project

Quantity

Item #

Model Specified:

 

CSI Section 11400

 

 

 

Specifications

Construction, Hardware and Insulation

Cabinet exterior front, louver assembly and doors are constructed of 20 gauge stainless steel. Cabinet sides (including returns), interior and door liners are constructed of anodized aluminum. The exterior cabinet top and bottom are constructed of heavy gauge aluminized steel. A set of four (4) 6" high casters are included.

Doors are equipped with a gasket protecting metal door pan, removable plug cylinder locks and guaranteed for life cam-lift, gravity action, self-closing metal, glide hinges with stay open feature at 120 degrees. Hinges include a concealed switch to automatically activate the interior incandescent lighting. Guaranteed for life, work flow door handles are mounted horizontally over recess in door which limits protrusion from door face into aisleways.

Easily removable for cleaning, vinyl magnetic door gasket assures tight door seal. Anti condensate heaters are located behind each door opening.

Both the cabinet and doors are insulated with an average of 2" thick high density, non-CFC, foamed in place polyurethane.

DIMENSIONAL DATA1-Section Models2-Section Models

Net capacity cu. ft.

25.6 (719 cu l)

48.8 (1371 cu l)

Length - overall in.

2978 (75.9 cm)

5218 (132.4 cm)

Depth - overall in.

371516 (96.4 cm)

371516 (96.4 cm)

Depth - over body in.

32 (81.3 cm)

32 (81.3 cm)

Depth - doors open 90° in.

8338 (211.8 cm)

8338 (211.8 cm)

Clear door width in.

2118 (53.6 cm)

2118 (53.6 cm)

Clear half-door height in.

2712 (69.9 cm)

2712 (69.9 cm)

Clear full-door height in.

5758 (146.3 cm)

5758 (146.3 cm)

Height-overall on 6" casters

8314 (211.5 cm)

8314 (211.5 cm)

No. Standard Shelves

3

6

Shelf area sq. ft.1

18.8 (1.75 sq m)

34.6 (3.21 sq m)

ELECTRICAL DATA

 

 

Voltage

115/60/1

115/60/1

Feed wires with Ground

3

3

Full load amperes

4.7

7.3

REFRIGERATION DATA

 

 

Refrigerant

R-134a

R-134a

BTU/HR H.P.2

1520 (14 HP)

2410 (13 HP)

SHIPPING DATA

 

 

Length - crated in.

35 (89 cm)

63 (160 cm)

Depth - crated in.

43 (109 cm)

43 (109 cm)

Height - crated in.

8312 (212 cm)

8312 (212 cm)

Volume - crated cu. ft.

71 (2011 cu l)

131 (3711 cu l)

Net Wt. lbs.

305 (138 kg)

450 (204 kg)

Gross Wt. lbs.

395 (179 kg)

590 (268 kg)

 

 

 

NOTES

NOTE: Figures in parentheses reflect metric equivalents.

1= Figure shown reflects the area of standard shelf compliment plus the additional storage area available on the cabinet bottom.

2= Based on a 90 degree F ambient and 20 degree F evaporator. For remote data please refer to spec sheet 13-2.

Refrigeration System

Atop mounted, self-contained, balanced refrigeration system using R-134a refrigerant is conveniently located behind the one piece louver assembly. It features an easy to clean front facing condenser, thermostatic expansion valve, air-cooled hermetic compressor, large, high humidity evaporator coil located outside the food zone and a top mounted non-electric condensate evaporator. A 9' cord and plug is provided. Standard operating temperature is 34 to 38°F.

Controller

The easy to use water resistant microprocessor control system is supplied standard. It includes a 3-Digit LED Display, and a Fahrenheit or Celsius Temperature Scale Display Capability.

Interior

Standard interior arrangements include three (3) epoxy coated wire shelves per section, mounted on shelf pins, installed at the factory. Shelves are full-width, and do not have any large gaps between them requiring the use of "bridge" or "junior shelves." Recommended load limit per shelf should not exceed 225 lbs.

Warranties

Both a one year parts and labor warranty and a five year compressor warranty (self- contained models only) are provided standard. An optional 2nd year extended parts and labor warranty is also available.

Equipped With One NEMA 5-15 P Plug

REQUIRED CLEARANCES

In order to assure optimum performance, the condensing unit MUST have an adequate supply of air for cooling purposes. Therefore, the operating location must either have a minimum of 12” clearance overhead of the condensing unit or allow for unrestricted air flow at the back of the unit. Clearance of at least 12” above is required in order to perform certain maintenance tasks.

NOTE: When ordering please specify: Voltage, Hinging, Door Size, Options and any additional warranties.

Continued product development may necessitate specification changes without notice. Part No. TR35885 (revised 6/08)

SECTION

TRAULSEN

 

4401 BLUE MOUND RD.

FT. WORTH, TX 76106

4-5

PHONE 1 (800) 825-8220

FAX-MKTG. 1 (817) 624-4302

Website: www.traulsen.com

Page 4