IV. CHANGING THE PRINTER PAPER:(continued) | VI. GLOSSARY OF ICONS: |
Press the red feed button to feed paper through the printer.
Replace the printer cover or close the printer door, taking care that the paper or label is passed through the paper slot on it’s front.
Chill By Temp | Standard Chill | Defrost |
Chill By Time | Speed Chill | Probe |
Chill By Product | Delicate Chill | Time Zone |
Product | Energy Saving Chill | Print Record |
Toolbox | User | Print Label |
VII. TROUBLESHOOTING: |
|
|
V.OPERATION:
IDLE MODE
STARTING A CHILL
CYCLE
THE RUN SCREEN
STARTING A CHILL CYCLE
AUTO:
1)Place probe in product (must be above 90 degrees F). The chiller will automatically begin a chill cycle in
OPTIONAL: Press any active probe(s) to enter the PRODUCT and/ or USER names.
MANUAL (by temp):
1)Place probe(s) in product.
2)Select MANUAL.
3)Adjust target TEMP and CHILL METHOD (if desired, default 37 degrees F).
OPTIONAL: Press any active probe(s) to enter PRODUCT and/or USER names.
4) Press START.
MANUAL (by time):
1)Load product in chiller.
2)Select MANUAL.
3)Adjust target TIME.
OPTIONAL: Press any time zone to enter product and or user names.
4) Press START.
CYCLE COMPLETION & PRINTING
Upon any probe reaching the target temperature the chiller will beep for
1)Press DONE.
No display on control. | a. Check power supply and circuit breaker. |
| b. System problem. Call for service. |
|
|
Cycle time longer than | a. Check if door is closed. |
expected. | b. Excessive volume or depth of product loaded. |
| c. Pan covered with a lid, plastic wrap or foil that is not in |
| direct contact with the product. |
| d. Dirty condenser coil. |
| e. Product is of a high density. |
| f. Evaporator coil iced and defrost needed. |
|
|
Auto start does not work. | a. Probe n/a. Press DONE to release probe for use. |
| b. Probe not placed in product. |
| c. Food probe placed in product below 1000F. |
| d. Damaged or defective probe. |
|
|
Chill cycle starts with no | a. Probes started automatically due to their temp rising to |
product present. | 1000F or more. |
|
|
Unwanted product | a. DONE product not removed and new chill cycle started. |
freezing. | Remove product when Done. |
| b. Chill cycle By Time set for too long. |
| c. High water content food. Use DELICATE method. |
|
|
Food drying out during | a. Food chilled uncovered. |
chilling. |
|
|
|
Printer not printing. | a. Printer is out of paper. |
| b. Printer paper may be installed incorrectly. Verify that the |
| thermal sensitive side of the paper. |
| c. Feed door open. |
| d. Paper does not feed or jams behind the paper feed slot in |
| the cover. Remove paper, reinstall correctly. |
|
|
Condensation on exterior | a. Check door alignment and gasket for proper seal. |
surface. | b. Check door sweep for proper adjustment |
| c. Electric door heater malfunction. Call for service. |
|
|
Product temp appears | a. Product temperatures within batches often vary. Verify |
cooler than expected. | product temperature using a thermometer. |
| b. Probe placed incorrectly. Relocate probe. |
| c. Product has very small mass (ex. chicken tender) use chill |
| by time. |
DATA
MANAGEMENT
OPTIONAL: Press PRODUCT and/or USER to enter the product and/or user names, if not done previously.
2)Press RECORD and/or LABEL (if equipped with optional label printer) to receive a cycle data printout and/or adhesive label. Repeat for additional copies if needed.
3)Press DONE to return to the RUN (if additional probes are active or done) or IDLE screens.
NOTE: Cycle data can also be downloaded via the USB port by selecting DATA MANAGEMENT in the TOOLBOX.
Many default settings can be adjusted, see full size owner’s manual for additional details.
d. Product held at room temperature too long prior to being |
placed in chiller. Verify actual product temp. |
VIII. SERVICE & PARTS:
Please visit our website @ traulsen.com for additional service and parts information. From our home page click on the SERVICE & PARTS tab, and select one of the following:
SERVICE FINDER
SERVICE PARTS MANUALS
OPERATOR MANUALS
WARRANTY REGISTRATION
| Traulsen |
| 4401 Blue Mound Road Fort Worth, TX 76106 |
| Phone: (800) |
| Parts Fax: (817) |
Quality Refrigeration | Website: traulsen.com |
© 2013 Traulsen - All Rights Reserved