Tricity Bendix SG558/1 user manual If a moulded plug is fitted, Connecting to gas supply

Models: SG558/1

1 40
Download 40 pages 8.97 Kb
Page 35
Image 35
If a moulded plug is fitted.

The wire, which is coloured blue, must be connected to the terminal, which is marked with the letter N or coloured black.

The wire, which is coloured brown, must be connected to the terminal, which is marked with the letter L or coloured red.

Ensure that the cable does not become trapped when pushing the appliance into position.

If a moulded plug is fitted.

In the event of replacing a fuse in the plug supplied a 3 amp ASTA approved fuse to B.S. 1362 must be fitted.

IMPORTANT!

The fuse cover must be refitted when changing the fuse. In the event of losing the fuse cover the plug must not be used until a replacement fuse cover has been obtained and fitted.

Connecting to gas supply

This appliance is designed to be installed with an appliance flexible connection only.

Supply piping should not be less than R3/8. Connection is made to the Rc ½ (½” B.S.P.) female threaded entry pipe located just below the hob level on the rear left hand side of the appliance.

IMPORTANT!

ONLY LIQUID SEALANTS TO BE USED WHEN INLET GAS PIPE IS FITTED I.E.: DO NOT USE P.T.F.E. SEALANT TAPE.

Carry out a gas tightness test after connecting to the gas supply.

The gas bayonet connector must be fitted in the shaded area indicated.

Take into account that it must be possible to pull the appliance forward sufficiently. Ensure the hose does not become trapped when pushing the appliance into position.

IMPORTANT!

FLEXIBLE TUBING USED MUST COMPLY WITH BS.669 CURRENT EDITION.

Fitting the stability chain

It is recommended that if the appliance is to be installed with a flexible supply pipe, a stability chain be fitted and is available from your supplier (see Important Safety Requirements). These instructions should be read in conjunction with any leaflet packed with the stability chain.

1.Place the appliance in its intended position and level appliance.

2.Mark a position 100mm from the top of the rear right hand corner.

3.Measure down 150mm from this point. This gives the position of the wall anchor point for the stability chain.

35

Page 35
Image 35
Tricity Bendix SG558/1 user manual If a moulded plug is fitted, Connecting to gas supply, Fitting the stability chain