Tricity Bendix TB 60 L Instructions for the Installer, Technical data, Installing the appliance

Models: TB 60 L

1 16
Download 16 pages 30.67 Kb
Page 12
Image 12
Instructions for the Installer

Instructions for the Installer

Technical data

Model

TB 60 L

Gross capacity (l)

Fresh food com.: 159

Net capacity (l)

Fresh food com.: 148

Width (mm)

550

Height (mm)

850

 

 

Depth (mm)

600

Energy consumption (kWh/day)

0.53

(kWh/year)

193

Energy class, according to EU Standards

B

Rated power (W)

100

Weight (kg)

34

Installing the appliance

Transportation, unpacking

The appliance and the interior fitting are protected for transport.

Remove all packaging and any adhesive tape.

Any remnants of adhesive can be removed using white spirit.

After transportation the appliance must not be switched on for 2 hours. This is to allow the refrigerant to settle.

Cleaning

Clean the accessories and the inside of the appliance with warm water and bicarbonate of soda (5 ml to 0.5 litres of water). Rinse and dry thoroughly.

Do not use detergents, abrasive powders, highly perfumed cleaning products, wax polishes or cleaning products containing bleach or alcohol.

Location

The appliance should be positioned in a well ventilated, dry room.

Energy use is affected by the ambient temperature. The appliance should therefore:

not be installed next to radiators, cookers or other sources of heat

only be installed at a location where the ambient temperature corresponds to the climate classification, for which the appliance is designed.

The climate classification can be found on the serial plate.

The following table shows which ambient temperature is correct for each climate classification:

Climate Classification

Ambient Temperature

 

 

SN

+10 to +32 °C

 

 

N

+16 to +32 °C

 

 

ST

+18 to +38 °C

 

 

12