SPECIFICATIONS
FM 1000 Electrostatic
Input Voltage: | 120 V, 60 HZ, 1 PH | |
Amp Draw: | 3.1 Max. | |
Unit Weight: | 108 lbs. | |
Air Output: | 600, 800 and 1100 CFM (nominal) | |
Options: | 1. | Charcoal After Filter |
| 2. | Remote Discharge |
| FM 1000 Media | |
Input Voltage: | 120 V, 60 HZ, 1 PH | |
Amp Draw: | 4.0 Max | |
Unit Weight: | 88 lbs. | |
Air Output: | 400, 500 and 650 CFM (nominal) | |
Options: | 1. | Charcoal After Filter |
| 2. | Remote Discharge |
This manual provides information for location, installation, operation and service of the FM 1000 E & M. Before installation and use of the air cleaner, carefully read these instructions to insure maximum benefits from the unit and to avoid needless service cost that result from improper installation.
FM 1000 E ELECTROSTATIC
The FM 1000 E electronic air cleaner is technically known as a
Air movement through the unit is controlled by its own blower system. As dirty air enters the unit, it passes through a
The
FM 1000M MEDIA FILTER
The FM 1000M with media filtration instead of an Ionizer/Collector cell utilizes the same type
to change the filter and wash the
The media main filter and charcoal
OPERATION
CONTROL SWITCH
The 3 position control switch located on the exposed side of the installed unit, controls the operation of the power supply and the speed of the fan: Low, Medium or High. (Power Supply not needed on FM 1000 Media Unit).
LED LIGHTS (Red not used on FM 1000M)
The green LED indicates the unit has electrical power and the switch has been turned to one of the 3 positions.
The Red LED indicates High Voltage (approximately 6800 VDC) is supplied to the Ionizer / Collector cell. (Red not used on Media unit).
FILTER ACCESS
The filter access screws located on the access door of the unit hold the access door closed, and are designed to automatically disconnect electrical power when the access door is opened (Item 6, Page 5). The access door may be removed for convenience of unit installation and cleaning once in operation.
INSTALLATION
Read instructions carefully before beginning installation.
CAUTION:
ELECTRONIC AIR CLEANERS CANNOT BE USED IN AREAS WHERE COMBUSTIBLE GASES OR VAPORS
ARE PRESENT. USE GLOVES DURING INSTALLATION TO PREVENT POSSIBLE INJURY FROM EXPOSED METAL.
T-BAR CEILING INSTALLATION
DO NOT INSTALL THE UNIT IN A
1.Installer must provide the 2/0 chain or other hanger material as required.
2.Carefully unpack the unit and check for damage incurred in shipment. Report any damage to the freight carrier and your TRION Representative immediately.