Section III – Service and Maintenance

1. SERVICING AND MAINTENANCE

Beyond an occasional wipe down with a damp cloth, the units need little in the way of maintenance.

However, the units are designed to collect airborne dirt and from time to time will require routine servicing to remove the accumulation.

The service interval varies considerably between applications, but typically will range from six weeks in a busy bar up to several months in a quiet office.

During normal operation, the unit will make an occasional snapping noise. This is caused by large pieces of dirt accumulating on the electronic filter and is not dangerous. The Trion SE400E & SE800E units have anti-arcing circuitry to eliminate the nuisance of constant arcing. If, however, the arcing occurs every minute or two, it is an indication that the unit needs cleaning.

When a service is due proceed as follows:

a)Remove pre-filter and either vacuum clean it or wash as described below.

b)To clean the electronic filter, soak it in a hot (not boiling), a strong non-caustic detergent solution cleaner.

Trion can supply an excellent detergent- TriDex- obtainable through your Dealer. Alternatively, a dishwasher detergent does an excellent job.

Soak the collector cell for several hours, then rinse with clean water. Do not physically try to rub the dirt off since this can cause damage to the filter.

c)Allow the filter to dry thoroughly - preferably overnight- and replace into the unit or alternatively use force air dry setting on the unit.

Trion has a policy of continuous product improvement, and reserves the right to make changes in design and specification without notice.