for equipment compatible with a 1/2 cycle transfer time
1250 watts continuous AC output in inverter mode, 1440 watts continuous AC output in AC mode
DoubleBoost inverter output supports momentary startup loads up to 200% of the continuous rating for up to 10 seconds
OverPower inverter output supports longer duration overloads to 150% for
3 stage, 30 amp battery charger with adjustable settings for wet/gel battery types offers fast, reliable battery recharging
Protected hardwire
Two
Reliability enhanced
3 position operating mode switch supports "AUTO" mode to enable automatic transfer between DC and AC modes,
Set of six front panel LEDs display AC/DC operational modes, overload status, DC voltage level, shutdown status and system fault status
Set of 4 configuration dip switches support wet/gel battery charging profiles, adjustable 135/145V high voltage auto transfer during overvoltages and selectable 75/85/95/105V AC low voltage auto transfer during brownouts
Resettable 8A charger AC input breaker and resettable 12A AC output breaker and automatic 2 speed cooling fan protect the inverter from load and temperature related failures
Grounding lug properly connects the inverter/charger system to earth ground or vehicle grounding system
Automatic overload and thermal shutoff safely turns off inverter as excessive loads or overheating conditions develop
Front panel remote control connector enables remote off/on switching (requires optional APSRM4 switch accessory). Optional APSRM4 accessory also includes user configurable jacks to support inverter shutoff or startup as a vehicle ignition is engaged.
Specifications
OVERVIEW
Intended Application | Emergency Home Power |
|
|
SYSTEM OVERVIEW |
|
Voltage compatibility | 12V DC / 120V AC |
|
|
Frequency | 60 Hz |
compatibility |
|
|
|
OUTPUT |
|
Output watts | 1250W (continuous) / 2500W (peak) |
|
|
Output nominal | 120V |
voltage |
|
|
|
Output voltage | LINE POWER (AC): Maintains 120V nominal sine wave output from line power source. INVERTER POWER (AC): |
regulation | Maintains PWM sine wave output voltage of 120 V AC |
|
|
Output frequency | 60 Hz (+/- 0.3 Hz) |
regulation |
|
|
|
Outlet quantity / type | Hardwire |
|
|
Overload protection | Includes 8A input breaker dedicated to the charging system and 12A output breaker for AC output loads |
|
|
Continuous output | 1250 |
capacity (watts) |
|
|
|
Peak output capacity | 2500 |
(watts) |
|
|
|
INPUT |
|
Input connection type | DC INPUT: Set of 2 DC |
|
|
Input cord length | DC INPUT: User supplies cabling. 6 gauge or larger (see manual). AC INPUT: attached 6 ft. AC line cord with plug |
|
|
Recommended | DC INPUT: Requires 12V DC input source capable of delivering 127A for the required duration (when used at full |
Electrical Service | continuous capacity - DC requirements increase during |
| 120V AC recommended |
|
|
Maximum input | DC INPUT: Full continuous load - 127A at 12V DC. AC INPUT: 12 amps at 120VAC with full inverter and charger load |
amps / watts | (6.3A max |
|
|