Tripp Lite APSRM4 owner manual Configuration continued, Group B DIP Switches

Models: APSRM4

1 13
Download 13 pages 43.23 Kb
Page 6
Image 6
Configuration (continued)

Configuration (continued)

Group B DIP Switches

B2 B1 Select AC Sharing—OPTIONAL

Your Inverter/Charger features a high-output battery charger that can draw a significant amount of AC power from your utility source or generator when charging at its maximum rate. If your unit is supplying its full AC power rating to its connected heavy electrical loads at the same time as this high charging occurs, the AC input circuit breaker could trip, resulting in the complete shut off of pass-through utility power.

To reduce the chance of tripping this breaker, all APS Inverter/Chargers may be set to automatically limit the charger output. This keeps the sum of the unit’s AC load and charge power within the circuit breaker rating. This charger-limiting function has two settings, allowing you to reduce the charger’s draw lower and lower, as needed, if the AC input circuit breaker keeps tripping under the normal AC loads of devices you have connected downline from the unit. The figures show how to set your DIP Switches for charger-limiting.

Select Battery Charger-Limiting Points—OPTIONAL

(factory setting)

“Most Limiting” (#B2 & #B1 Up): B4 B3 B2 B1 Charger-limiting takes effect the moment Group B DIP SwitchesManual background any 120V AC load is applied; charger

output falls gradually from full output at no 120V load passing through to no output at full load.

“Less Limiting” (#B2 Up & #B1 Down):

B4 B3 B2 B1

Charger-limiting begins when the Inverter/Charger’s load reaches 33% of the Inverter/Charger’s load rating. Charger output falls gradually from full output at

33% of the Inverter/Charger’s load rating to about 40% of full output at full load.

B3

Select Equalize Battery Charge—OPTIONAL

 

 

 

 

 

 

 

 

 

Setting Procedure

 

 

This DIP Switch is momentarily engaged

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Move to “Equalize” (DOWN) position for three seconds.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B4

 

B3

 

B2

 

 

B1

Reset

 

to begin the process of equalizing the

 

 

 

 

 

Move to “Reset” (UP) position and leave it there. This is the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

charge state of your battery’s cells by time-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

factory default setting.

 

 

limited overcharge of all cells. This can

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION: Do not leave DIP switch #B3 in the down position after beginning process. Battery

 

 

 

 

 

 

 

 

 

 

 

 

 

Equalize

 

extend the useful life of certain types of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

charge equalization should only be performed in strict accordance with the battery manufacturer’s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

instructions and specifications.

 

 

batteries; consult with your battery’s manufacturer to determine if

 

 

 

 

 

 

your batteries could benefit from this

process. The

charge

Battery Charge

Switch Position

 

equalization process is automatic; once started,

it

can only be

Reset

Up (factory setting)

 

stopped by removing the input power.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Equalize

Down—momentarily

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery Charger

Switch Position

 

B4

Set Battery Charging Amps—OPTIONAL

 

 

 

 

 

 

 

 

 

 

 

Check the nameplate for your unit’s high-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low Charge Amps

Up (factory setting)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and low-charging amp options. By setting

 

B4

 

B3

 

B2

 

B1

 

 

 

 

 

 

High Charge Amps

Down

on high charging, your batteries will

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

charge at maximum speed. When setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION: When switching to the High Charge Amp setting, the user must ensure that the

on low charging, you lengthen the life of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

amp hour capacity of their battery system exceeds the amperage of the High Charge Amp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

your batteries (especially smaller ones).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

setting or the batteries may be damaged or degraded.

6

Page 6
Image 6
Tripp Lite APSRM4 owner manual Configuration continued, Group B DIP Switches