Tripp Lite is250hg warranty Specifications, Overview, Input, Physical

Models: is250hg

1 3
Download 3 pages 55.19 Kb
Page 2
Image 2

Internal low-impedance isolation transformer with Faraday shield offers 100% isolation from the input AC line

Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles; ideal for the protection of sensitive electronic equipment in patient-care areas.

Reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps

Secondary neutral-to-ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment

Serves as an inexpensive alternative to dedicated circuits and site electrical upgrades

Removes EMI/RFI noise, utility switching transients, load-generated harmonics and ground loops

Additional surge suppression components placed at the line input and output combined with full line isolation provide continuous filtering of a full range of power line noise in all modes

Active transformer filtering offers continuous common-mode noise rejection with no wearable parts; unique ability to reduce surges in the worst of power environments to harmless levels

Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode

Includes 2 widely spaced NEMA 5-15R hospital-grade output receptacles, a 6-ft. power cord, hospital-grade input plug, circuit breaker overload protection and lighted power switch.

Rugged all-metal unit housing; ships ready for upright tower placement in any industrial, medical, office or network environment 2-year limited product warranty

Specifications

OVERVIEW

Amp Capacity

2.1A at 120V AC

 

 

Efficiency

96%

 

 

Form Factor

Small tower format

 

 

Input Plug Type

NEMA 5-15P-HG Hospital-Grade

 

 

Leakage Current

Less than 100 microamps

 

 

Let-through Voltage

L-N: 250V L-G: 250V N-G: 0.5V

(Combination Wave)

 

 

 

Let-through Voltage (Ring

L-N: 20V L-G: 20V N-G: 0.5V

Wave)

 

 

 

Noise Suppression Rating

35-65 DB

 

 

Nominal Voltage / Frequency

120V/60Hz

 

 

Output Receptacle Qty / Type

2 NEMA 5-15R-HG Hospital-Grade

 

 

Over Current Protection

2A circuit breaker

 

 

Shipping Weight

13.80 lbs. / 6.26 kg

 

 

Suppression Joule Rating

940 joules

 

 

Surge Test Conditions

Per ANSI/IEEE C62.41 - IEEE587 Cat. A & B test waveforms

 

 

Total Harmonic Distortion

Less than 1%

 

 

Transformer Type

Medical grade, low impedance transformer-based line isolation transformer

 

 

Unit Dimensions (HWD/in.)

4.5 x 4.75 x 7.75

 

 

VA / Watt Capacity

250

 

 

Warranty

2-year limited product warranty

 

 

INPUT

 

Input cord length

6.00 ft./1.83 m

 

 

PHYSICAL

 

Cooling method

Convection

Page 2
Image 2
Tripp Lite is250hg warranty Specifications, Overview, Input, Physical