AC suppression joule rating

Clamping voltage (RMS)

AC suppression response time

AC suppression surge current rating

AC suppression components used

Safe thermal fusing

UL1499 let through rating

IEEE587 Cat. A ringwave let through

EMI / RFI filtering

Isolated filter banks

Immunity

2850 joules

140V

NM = 0 ns. CM =

92,000 amps (36,000 NM / 56,000 CM)

Metal oxide varistors, toroidal balanced chokes, ferrite rod-core inductors and VHF capacitors.

Prevents unsafe conditions during extreme extended over-voltages and catastrophic occurrences

330V - UL Verified

Less than 35 volts

40-80 dB

Unique isolated filter bank design offers additional filtering between each duplex pair of outlets on the strip to prevent electrical noise interference between connected loads. Includes 4 filter banks.

Conforms to IEE 587 / ANSI C62.41

DATALINE SURGE SUPPRESSION

Telephone/DSL

Yes

Protection

 

 

 

Telephone/DSL

1 line

Protection Details

 

 

 

Cable (Coax) Protection

No

 

 

Network (Ethernet)

No

Protection

 

 

 

PHYSICAL

 

Unit Dimensions

2.5 x 9 x 3.5

(HWD/in)

 

 

 

Unit Dimensions

6.4 x 22.9 x 8.9

(HWD/cm)

 

 

 

Material of construction

Metal

 

 

Integrated keyhole

Metal end caps are fitted with keyhole mounting tabs for wallmount installation

mounting tabs

 

 

 

Receptacle Color

Black

 

 

AC line cord color

Gray

 

 

Style

Strip

 

 

SPECIAL FEATURES

 

Appearance

Rugged all-metal corded strip format with high quality duplex receptacles

 

 

CERTIFICATIONS

 

UL1449 1998 Rev. (AC

UL1449

Suppression)

 

 

 

UL1283 (EMI Filter)

UL1283

 

 

UL1363 (Power Tap)

UL1363

 

 

UL497A

UL497A

(Communications)

 

 

 

FCC Part 68

FCC Part 68

(Communications)

 

 

 

cUL / CSA (Canada)

cUL

Page 3