Voltage regulation description
Overvoltage correction
Direct pass through
Brownout correction
Severe brownout correction
Automatic Voltage Regulation (AVR) circuits maintain clean, regulated
Input voltages between 128 and 147V AC are reduced by 12%
Input voltages between 108 and 127V AC are passed on to connected equipment unchanged
Input voltages between 93 and 107V AC are boosted by 14%
Input voltages between 75 and 92V AC are boosted by 30%
LEDS ALARMS & SWITCHES
Front panel LEDs
Alarms
Switches
5 front panel LEDs indicate line power status, battery power status, battery low/replace status, voltage regulation operation and overload status
Audible alarm with 15 second delay sounds to indicate loss of utility power. Alarm can be silenced by pressing front panel alarm cancel button. Once silenced, alarm will
Includes 2 front panel switches — one main on/off power switch and one dual function "alarm cancel" / "self test" button
SURGE / NOISE SUPPRESSION
AC surge suppression | 480 joules |
|
|
AC suppression | Instantaneous |
response time |
|
|
|
Dataline suppression | - |
|
|
EMI / RFI AC noise | Yes |
suppression |
|
|
|
PHYSICAL |
|
Shipping weight (lbs) | 40 |
|
|
Shipping weight (kg) | 18.2 |
|
|
Unit weight (lbs) | 36.4 |
|
|
Unit weight (kg) | 16.5 |
|
|
Unit Dimensions | 12.75 x 7.5 x 9 |
(HWD/in) |
|
|
|
Unit Dimensions | 32.4 x 19.1 x 22.9 |
(HWD/cm) |
|
|
|
Material of | PVC |
construction |
|
|
|
Form factors | Tower |
supported |
|
|
|
Cooling method | Convection |
|
|
Battery Access | Battery access door allows user replacement of UPS batteries. |
|
|
ENVIRONMENTAL |
|
Relative Humidity | 0 to 95%, |
|
|
Storage Temperature | +5 to +122 degrees Fahrenheit, |
|
|
Operating | +32 to +104 degrees Fahrenheit, 0 to +40 degrees Celsius |
Temperature |
|
|
|
COMMUNICATIONS |
|
Network monitoring | USB |
port |
|
|
|
Software and cabling | USB cabling included, PowerAlert software available for free download at www.tripplite.com |
included |
|
|
|
WatchDog | Compatible with Tripp Lite's Watchdog system service to restore operation to locked equipment through soft reboot of |
compatibility | application / OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications |
|
|