￿OmniSmart 450 Hospital-Grade UPS System

￿RS-232 remote monitoring cable

￿Instruction manual with warranty information

COMPLETE SPECIFICATIONS

SYSTEM OVERVIEW

System overview:

Voltage compatibility:

Frequency compatibility:

OUTPUT

Output volt amp capacity (VA):

Output watt capacity (watts):

Output nominal voltage:

Output voltage regulation:

Output frequency regulation:

Outlet quantity / type:

INPUT

Maximum input amps:

Input connection type:

Input cord length:

Recommended electrical service:

BATTERY

Full load runtime:

Half load runtime:

DC system voltage:

Typical battery lifespan:

Battery recharge rate:

VOLTAGE REGULATION

Voltage regulation description:

Overvoltage correction:

Direct pass through:

Brownout correction:

Severe brownout correction:

LEDS ALARMS & SWITCHES

Front panel LEDs:

Alarms:

Line Interactive UPS system with hospital grade plug and outlets, meets, line interactive voltage regulation, AC surge suppression and DB9 communications port

120 V AC

60 Hz

450

280

120V nominal

LINE MODE: Sine wave line voltage 120V (-18% / +8%)

BATTERY MODE: PWM sine wave output 120V +/-5%

LINE MODE: Passes line frequency of 60Hz. +/-10%

BATTERY MODE: Inverter output regulated to 60Hz +/-0.5Hz

4 NEMA5-15R Hospital Grade Output Receptacles

2.8A / 320 watts

NEMA 5-15P Hospital-Grade

6 ft, 14 gauge

15A 120V

5 minutes (450VA)

17 minutes (225VA)

12 VDC

3-6 years, depending on usage

2-4 hours to 90%

Automatic Voltage Regulation (AVR) circuits maintain clean, regulated computer-grade 120V nominal output, without using battery power, during brownouts to 75V and overvoltages to 147V

Input voltages between 128 and 147V AC are reduced by 12%

Input voltages between 108 and 127V AC are passed on to connected equipment unchanged

Input voltages between 93 and 107V AC are boosted by 14%

Input voltages between 75 and 92V AC are boosted by 30%

4 front-panel indicator LEDs show line power status, battery power status, battery low/replace status and voltage regulation operation

Audible alarm indicates power failure conditions, silenceable via alarm cancel switch. Once cancelled, alarm will resume when approximately 2 minutes of battery operation remain

Page 2
Image 2
Tripp Lite OMNISMART450HG warranty Complete Specifications