Model Number: PDUBHV10

Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: saleshelp@tripplite.com

Model Number: PDUBHV10

Single-Phase Hot-Swap PDU, 2-2.4kW 10A 200-240V, 2U Horizontal Rackmount, 8 C13 outlets, set of 2 C14 inputs

Highlights

Highlights Single phase 10A 200-240V Hot-swap PDU

Description Enables live replacement of a standard UPS with zero downtime

Applications 2U horizontal rackmount installation

Package Includes Compatible with any 200-240V UPS with a C14 input

Features Manual transfer switch controls PDU input power source

Manual background Pair of C14 compatible inputs connect to separate Utility and UPS inputs

Manual background 8 Built-in C13 outlets

Description

Tripp Lite’s Hot-swap PDU systems enable live-replacement of standard UPS systems for maintenance with no interruption of connected server or networking loads. Dual input power cables support PDU connection to separate Utility and UPS power sources. Manual transfer switch with lighted status indicators controls the source of power to connected equipment between Utility and UPS. Set the switch to UPS during normal operation and connected equipment will receive full-time conditioned power from the UPS. Set the switch to Utility to momentarily power connected equipment from the Utility line cord and bypass the UPS while the UPS system is removed and replaced with a fresh one. Once the new UPS is up and running with all data and electrical connections restored, set the switch back to the UPS setting to once again provide fully-conditioned UPS power to connected equipment.

Applications

Hot-swap PDUs are ideal to install along with standard UPS systems to ensure that connected networking equipment will see no power interruption

as the UPS is serviced, replaced or upgraded

Package Includes

Manual background Hot-swap PDU System

Manual background 2U mounting brackets

Manual background Set of 2 C13-C14 interconnect cables

Manual background User manual with warranty information

Features

Manual background Tripp Lite Hot-swap PDU systems support live-replacement of standard UPS systems for maintenance with no interruption of connected server or networking loads

Manual background PDUBHV10 is universally compatible with any Tripp Lite or other brand of 200-240V UPS rated up to 1500VA with a C14 input cable option

Manual background 2U horizontal rackmount form factor compatible with 2 or 4 post racks

Manual background Supports space saving rear-post mounting in the same rack space as many Tripp Lite Rackmount UPS systems (select installations, see manual)

Manual background Pair of detachable PDU input cables connect to separate Utility and UPS power sources (2 C13-C14 interconnect cables included - user supplied alternate cabling supported)

Manual background 8 C13 outlets support critical networking loads in both Utility and UPS operating modes

Manual background One additional C13 pass-through outlet supports UPS input power cord

Manual background Dual input power cables support PDU connection to separate Utility and UPS power sources

Manual background Manual transfer switch with lighted status indicators controls the source of power to connected equipment between Utility and UPS