Maintenance & Service

Your Inverter requires no maintenance and contains no user-serviceable parts (except for replaceable DC fuses). If returning your Inverter to Tripp Lite, please pack it carefully using the ORIGINAL PACKING MATERIAL that came with the unit. Enclose a letter describing the problem. If the Inverter is within the warranty period, enclose a copy of your sales receipt. To obtain service you must obtain a Returned Material Authorization (RMA) number from Tripp Lite or an authorized Tripp Lite service center.

Limited Warranty

Tripp Lite warrants its Inverters to be free from defects in materials and workmanship for a period of 1 year from the date of initial purchase. Tripp Lite’s obligation under this warranty is limited to repairing or replacing (at its sole option) any such defective products. To obtain service under this warranty you must obtain a Returned Material Authorization (RMA) number from Tripp Lite or an authorized Tripp Lite service center. Products must be returned to Tripp Lite or an authorized Tripp Lite service center with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase.

This warranty does not apply to equipment which has been damaged by accident, negligence or misapplication or has been altered or modified in any way, including opening of the unit’s casing for any reason. This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase.

EXCEPT AS PROVIDED HEREIN, TRIPP LITE MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some states do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser.

EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, Tripp Lite is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise.

Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.

Troubleshooting

 

Please check the following before sending the Inverter in for service:

 

 

 

 

Symptom

 

Problem

 

Correction

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm sounds.

 

Low battery voltage (<10.5 V).

 

Turn Inverter OFF and run engine to recharge

 

 

 

 

 

 

vehicle battery.

 

 

 

 

 

 

 

 

 

 

 

Output overload.

 

Turn Inverter OFF and remove overload by unplugging

 

 

 

 

 

 

high-wattage devices. Load should not exceed your

 

 

 

 

 

 

Inverter's maximum continuous output power

 

 

 

 

 

 

(see Specifications).

 

 

Inverter does not turn ON when power switch is turned ON.

 

Automatic Inverter shutdown due to low battery voltage (<10V).

 

Turn Inverter OFF and run engine to recharge

 

 

 

 

 

 

vehicle battery.

 

 

 

 

 

 

 

 

 

 

 

Automatic Inverter shutdown due to output overload.

 

Turn Inverter OFF and remove overload by unplugging

 

 

 

 

 

 

high-wattage devices. Load should not exceed your

 

 

 

 

 

 

Inverter’s maximum continuous output power

 

 

 

 

 

 

(see Specifications).

 

 

 

 

Blown fuse.

 

Replace fuse with standard automotive fuse of identical

 

 

 

 

 

 

amperage (see Specifications).

 

 

Inverter is unable to power connected equipment.

 

Battery running low. Low battery voltage reduces

 

Turn Inverter OFF and run engine to recharge

 

 

 

 

Inverter power output.

 

vehicle battery.

 

 

 

 

 

 

 

 

 

 

 

Connected equipment load exceeds Inverter’s maximum

 

Turn Inverter OFF and remove overload by unplugging

 

 

 

 

continuous output power.

 

high-wattage devices. Load should not exceed your

 

 

 

 

 

 

Inverter's maximum continuous output power

 

 

 

 

 

 

(see Specifications).

 

 

Connected equipment experiences audio/video distortion.

 

Loose connections.

 

Check and secure all connections.

 

 

 

 

Audio/video interference.

 

Reposition equipment antennas and Inverter.

 

 

 

 

 

 

 

 

 

Specifications

 

 

 

 

 

 

 

 

 

 

 

 

Model:

PV150

PV375

PV500

PV600

Output Power (Maximum Continuous Watts):*

150

375

500

600

Output Power (Peak Watts):**

300

600

1000

1000

Input Voltage (DC):

12V nominal (10-15V)

12V nominal (10.5-15V)

12V nominal (10-15V)

12V nominal (10-15V)

Output Voltage (AC)/Frequency:

120V / 60 Hz. nominal

120V / 60 Hz. nominal

120V / 60 Hz. nominal

120V / 60 Hz. nominal

Output Waveform:

PWM Sine Wave

PWM Sine Wave

PWM Sine Wave

PWM Sine Wave

Low Battery Voltage Alarm (Volts):

10.5V

10.5V

10.5V

10.5V

Low Battery Voltage Shutdown (Volts):

10V

10V

10V

10V

AC Outlets:

1

2

3

3

Circuit Protection (DC Overload):

20-amp fuse (external)

40-amp fuse (external)

Two 40-amp fuses (internal)

Two 40-amp fuses (internal)

*Maximum output power (continuous or peak) only available when vehicle battery is properly charged. Run vehicle engine often to maintain proper charge. ** Peak Output Power is instantaneous. The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.

Typical Runtimes Before Battery Recharge

Although you can operate your Inverter with your vehicle engine off, best results are usually attained with the engine running. Since the Inverter converts electrical energy (and doesn’t produce it), the Inverter’s performance is relative to the condition of your vehicle’s electrical system (battery, alternator and wiring). If other loads (air conditioner, heater, lights, etc.) are also using power, you may get less runtime.

 

With Typical

With Typical

With Typical

 

 

Compact Vehicle (4 cylinder)

Mid-Size Vehicle (6 cylinder)

Full-Size Vehicle (8 cylinder)

 

Battery, Alternator

Battery, Alternator

Battery, Alternator

 

& Wiring

& Wiring

& Wiring

 

 

 

 

 

Model: PV150

 

 

 

 

 

 

 

 

 

1/2 Load (engine on/engine off)

continuous/4-6 hours

continuous/6-8 hours

continuous/8-12 hours

 

 

 

 

 

Full Load (engine on/engine off)

continuous/2-3 hours

continuous/3-4 hours

continuous/4-6 hours

 

 

 

 

 

Model: PV375

 

 

 

 

 

 

 

 

 

1/2 Load (engine on/engine off)

continuous/1-2 hours

continuous/2-3 hours

continuous/3-6 hours

 

 

 

 

 

Full Load* (engine on/engine off)

continuous/30 min-1 hour

continuous/1-2 hours

continuous/2-3 hours

 

 

 

 

 

Models: PV500 & PV600

 

 

 

 

 

 

 

 

 

1/2 Load (engine on/engine off)

continuous/not recommended

continuous/1 hour

continuous/2 hours

 

 

 

 

 

Full Load (engine on/engine off)

1-2 hours/not recommended

2-4 hours/not recommended

continuous/1 hour

 

 

 

 

 

* If vehicle wiring is adequate. See “Vehicle Electrical System Limitations” at right.

Minimum Recommended Cable Sizing Chart (PV500 & PV600 only) Choose the correct wire gauge based on your equipment’s wattage load.

 

 

 

 

 

Wire Gauge

 

 

 

 

Watts

10 ga.

8 ga.

Two 10 ga.

6 ga.

4 ga.

100

24

ft.

36

ft.

48

ft.

56

ft.

100 ft.

200

12

ft.

18

ft.

24

ft.

28

ft.

48

ft.

 

 

 

 

 

 

 

 

 

 

 

300

8

ft.

12

ft.

16

ft.

20

ft.

30

ft.

 

 

 

 

 

 

 

 

 

 

 

400

6

ft.

10

ft.

12

ft.

14

ft.

24

ft.

 

 

 

 

 

 

500

not recommended

8 ft.

10 ft.

12 ft.

18 ft.

 

 

 

 

 

 

600

not recommended

6 ft.

8 ft.

10 ft.

15 ft.

Note: acceptable power is directly related to cable length (i.e.: the shorter the cable, the better the performance).

Vehicle Electrical System Limitations

NOTE: Due to the limitations of certain vehicles’ 12V DC lighter/accessory outlet electrical systems, you may not be able to continuously run a full load (375 watts) from PV375 models. If you regularly blow fuses, it may indicate your vehicle is not adequately wired to support a PV375 as it is designed. In this case, consult vehicle manufacturer recommendations for rewiring from the fuse block or battery with appropriate wiring (10 - 12 gauge) and fusing (at least 40 amp). All standard vehicle accessory outlet electrical systems can support full loads for PV150 models without any modifications.

Copyright © 2003 Tripp Lite. All rights reserved. PowerVerter is a registered trademark of Tripp Lite.

200301121 93-2112

 

Page 2
Image 2
Tripp Lite PV375, PV600, PV500 owner manual Maintenance & Service, Limited Warranty, Troubleshooting, Specifications