Tripp Lite SRXCOOL33K warranty Highlights, Description, Applications, Package Includes, Features

Models: SRXCOOL33K

1 3
Download 3 pages 51.45 Kb
Page 1
Image 1
Tripp Lite

Tripp Lite

1111 West 35th Street

Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: saleshelp@tripplite.com

Model Number: SRXCOOL33K

33,000 BTU Energy-Saving, Row-Based Air Conditioning Unit with Hardwire Input

Highlights

1111 West 35th Street 33,000 BTU (9.7kW) of cooling power with 1/3 less power consumption

Model Number: SRXCOOL33K Variable-speed, DC-inverter-driven compressor and microprocessor-controlled

electronic expansion valve (EEV) enable precision cooling adjustments--no

more wasteful, noisy cycling between off and full blast

Highlights Soft-start feature limits inrush current to prevent introduction of line noise,

voltage disruptions and potential circuit overloads

Description Self-contained, zero-maintenance unit re-humidifies condensate and expels it

through the exhaust air stream--no floor drain, water collection tank, external

condenser, refrigerant piping, duct work or plumbing required

Applications Hardwire Input (User-supplied IEC 309 32-amp set, optional) - no electrician

needed

Package Includes 200-240V AC Input, 50/60 Hz frequency compatibility

Features 1 year limited warranty

Description

The harder your data center, network closet or server room works, the more it heats up, leading to inefficient operation, weakened performance and raised cooling costs. In fact, cooling can consume more than half of the power used by a high-density installation—start saving power and money with Tripp Lite’s SRXCOOL33K today! The SRXCOOL33K provides 33,000 BTU of efficient, reliable cooling in a 42U rack form factor. It features cutting-edge components that limit inrush current and enable precision cooling adjustments to minimize power consumption, maximize cooling and improve your application efficiency.

By delivering cold air high in the cold aisle, the SRXCOOL33K promotes temperature uniformity from 1U to 42U, allowing your equipment to perform at its peak. Controlling the unit is simple with the intuitive LCD display, or control it from anywhere in the world with the included Modbus card or an optional network interface (Tripp Lite SNMPWEBCARD, sold separately). With hardwire input (user supplied IEC 309 32-amp set, optional) and exhaust connection directly into the drop ceiling, you can install the unit with no electrician or contractor necessary, saving on up-front installation costs. Maintenance is no-hassle due to the self-contained design, which requires no water collection tank or extra plumbing, while RoHS compliance and eco-friendly R410a refrigerant means you’ll never have to worry about meeting environmental standards.

Applications

Supplemental cooling of data center equipment in confined areas where the facility HVAC is inadequate or doesn't reach.

Package Includes

Manual background SRXCOOL33K Air Conditioning Unit

Manual background Flexible Air Ducts

Manual background Unpacking Guide, Installation Manual and Owner’s Manual

Manual background Unloading Ramps

Manual background Hot Exhaust Removal Tube

Manual background Owner's Manual

Features

Manual background 33,000 BTU (9.7kW) of cooling power with 1/3 less power consumption

Manual background Variable-speed, DC-inverter-driven compressor and microprocessor-controlled electronic expansion valve (EEV) enable precision cooling adjustments--no more wasteful, noisy cycling between off and full blast

Manual background Soft-start feature limits inrush current to prevent introduction of line noise, voltage disruptions and potential circuit overloads Manual background Self-contained, zero-maintenance unit re-humidifies condensate and expels it through the exhaust air stream--no floor drain, water