Specifications

OUTPUT Supports connected equipment during blackouts for 20/7 minutes at half/full load levels, runtime is further expandable with optional external BP192V18-4U battery packs

Output kVA capacity (kVA) Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)

Output power factor Network interfaces support simultaneous communications via DB9 port, USB port and SNMPWEBCARD slot. DB9 port supports RS-232 and dry contact messaging. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X.

Nominal Voltage details Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP

Output voltage regulation (Battery mode) Communications ports support on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, AC line frequency, timed inverter shutoff, activate self-test and output power control

Manual background Built-in Emergency Power Off (EPO) interface with cable

Manual background Includes 13 output receptacles (2 L6-30R, 6 C19, 5 NEMA 5-15/20R) plus hardwire output, all of which are available for simultaneous use

Manual background Split phase, 4 conductor hardwire input connection (featured on included detachable PDU).

Manual background Front panel LEDs and LCD readout with scroll button enables visual confirmation of all major UPS functions and current site electrical conditions

Manual background Front panel switches enable power on/off control, self-test and alarm cancel functions

Manual background Included adjustable mounting rails support installation in 4 post 19 inch rack enclosures

Manual background Optional 2-9USTAND set of tower stands supports upright tower installation

Manual background Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions Manual background $250,000 Ultimate Lifetime Insurance (USA, Puerto Rico and Canada only)

Specifications

OUTPUT

Output Volt Amp Capacity (VA)

Output kVA capacity (kVA)

Output Watt Capacity (watts)

Output kW capacity

Output power factor

Output Capacity

Details

Crest Factor

Nominal Output Voltage(s) Supported

Nominal Voltage details

Frequency compatibility

Output voltage regulation (line mode)

Output voltage regulation (Economy line mode)

12000

12

8400

8.4

0.7

12,000 VA (240V) / 10,395 VA (208V) / 8400 watts (208/240V)

3:1

120V; 208V; 240V

240/120V or 208/120V split phase output

60Hz

+/- 3%

+/- 10%

Output voltage regulation (Battery mode)

+/- 3%

Built-in UPS output receptacles

5 5-15/20R outlet(s); 2 L6-30R outlet(s); 6 C19 outlet(s); Hardwire