TVS electronic RP-3200 Dip Switch Setting, Serial Interface Specification, Baud rate selection

Models: RP-3200

1 28
Download 28 pages 383 b
Page 12
Image 12
2-4. Dip Switch Setting

Jus' Print RP-3200 User’s Manual

2-4. Dip Switch Setting

The printer is set up at the factory to be appropriate for almost all users. On the other hand, offers some more settings for users with special requirements.

It has DIP switches that allow you to change communication setting, such as handshaking and parity check, as well as print density.

Your printer has two sets of DIP switches. The functions of the switches are shown in the following tables.

♣Note : Power off. And open the cover of Dip Switch and change setting.

2-4-1. Serial Interface Specification

DIP Switch Set 1 Functions

SW

FUNCTION

ON

OFF

DEFAULT

1

Data Receive

Ignored

Print “?”

OFF

2

Hexadecimal

HEXDUMP

NORMAL

OFF

3

Hand Shaking

XON/XOFF

DTR/DSR

OFF

4

Data Length

7bits

8bits

OFF

5

Parity Check

ENABLED

DISABLED

OFF

6

Parity Check

EVEN

ODD

OFF

Baud rate selection

Transmission speed

SW-7

SW-8

4800 bps

ON

ON

9600 bps

OFF

ON

19200 bps

ON

OFF

38400 bps

OFF

OFF

Print Density (DIP-SW2)

Print Density

SW-1

SW-2

Low Power

ON

ON

Normal

OFF

ON

Normal

ON

OFF

Dark

OFF

OFF

11

Page 12
Image 12
TVS electronic RP-3200 Dip Switch Setting, Serial Interface Specification, DIP Switch Set 1 Functions, Baud rate selection