6-5. Environmental Requirements

Jus' Print RP-3200 User’s Manual

!Important!

When connecting or disconnecting the power supply from the printer, be sure that the following cautions are observed.

(1)Use a power supply (Limited Power Supply) of DC 24V±10% and more than 2.5A.

(2)Be careful about installing the printer in an area where there is noise.

(3)Take the appropriate measure to protect against electrostatic AC line noise, etc.

6-5. Environmental Requirements

(1) Operating

 

Temperature

5°C to 40°C

Humidity

10% to 90% RH (without condensation)

(2) Transport/Storage (except paper)

Temperature

-20°C to 60°C

Humidity

10% to 90% RH (without condensation)

6-6. Reliability

(1)

MCBF

60 million lines (based on an average printing rate of 12.5% with paper

 

 

thickness in the range of from 65µm - 75µm)

 

 

35 million lines (based on an average printing rate of 12.5% with paper

 

 

thickness in the range of from 76µm - 150µm)

(2)

Head Life

100 million pulses, 100Km

(3)

Cutter Life

1.0 million cuttings (if the paper thickness is between 65 and 100µm)

6-7. Certification

(1)FCC PART15 CLASS A

(2)CE EMCD/LVD

(3)UL/cUL

(4)MIC

(5)RoHS