Guidance and manufacturer’s declaration-electromagnetic immunity- for all EQUIPMENT AND SYSTEMS that are not LIFE-SUPPORTING

Guidance and manufacturer’s declaration-electromagnetic immunity

The ET1928L is intended for use in the electromagnetic environment specified below. The user of the ET1928L should assure that it is used in such an environment.

Immunity test

IEC 60601 test level

Compliance

Electromagnetic environment-guidelines

 

 

level

 

 

 

 

 

 

 

 

Portable and mobile RF communications equipment

 

 

 

should be used no closer to any part of theET1928L,

 

 

 

including cables, than the recommended separation

 

 

 

distance calculated from the equation applicable to

 

 

 

the frequency of the transmitter.

 

 

 

Recommended separation distance

Conducted RF

3 Vrms

3 Vrms

d=1.2 P

Radiated RF

3 V/m

3 Vrms

d=1.2 P 80MHz to 800 MHz

IEC 61000-4-3

80 MHz to 2.5 GHz

 

 

 

 

 

d=2.3 P 800 NHz to 2.5GHz

 

 

 

where P is the maximum output power rating of

 

 

 

the transmitter in watts (W) according to the

 

 

 

transmitter manufacturer and d is the recommended

 

 

 

separation distance in metres(m)

 

 

 

Filed strengths from fixed RF transmitters, as

 

 

 

determined by an electromagnetic site survey 3,

 

 

 

should be less than the compliance level in each

 

 

 

frequency range4.

 

 

 

Interference may occur in the vicinity of

 

 

 

equipment marked with the following symbol:

 

 

 

 

NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.

NOTE 2 These guidelines may not apply in all situation. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.

3.Filed strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured filed strength in the location in which the ET1928L is used exceeds the applicable RF compliance level above, the ET1928L should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the ET1928L.

4.Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 Vrms.