IntelliTouch(acoustic) Touchmonitor Specifications
Mechanical
Positional Accuracy
Touchpoint Density
Touch Activation
Force
Surface Durability
Expected Life
Performance
Sealing
Optical
Light Transmission
(per ASTM D1003)
Visual Resolution
Gloss (per ASTM D2457 using a 60- degree gloss meter)
Standard deviation of error is less than 0.080 in. (2.03 mm). Equates to less than ±1%.
More than 100,000 touchpoints/in2 (15,500 touchpoints/cm2). Typically less than 3 ounces (85 grams).
Surface durability is that of glass, Mohs’hardness rating of 7. No known
Unit is sealed to protect against splashed liquids, dirt, and dust.
IntelliTouch 92%, AccuTouch 82%.
All measurements made using USAF 1951 Resolution Chart, under 30X magnification, with test unit located approximately 1.5 in (38
mm)from sur face of resolution chart. Clear surface: Excellent, with no noticeable degradation. Antiglare surface: 6:1 minimum. Antiglare surface: Curved: 60 ±20 gloss units or 75 ± 15 gloss units.