Tyco DCM 150 manual Technical Specifications, Product Highlights, Ease of Installation

Models: DCM 150

1 2
Download 2 pages 17.47 Kb
Page 2
Image 2
Product Highlights

CEM/B/040 Rev C

Product Highlights

Connect to existing read head technology

The DCM 150 is suitable for installations where customers want to connect existing read head technology to any of CEM’s intelligent controller products like webEntry or the S9032/ S9064 with AC2000 SE. Unlike the CEM range of card readers the DCM 150 does not provide local database support for off-line card validation.

Ease of Installation

Visual confirmation of board, relay and comms transmit/receive

status is provided via LEDs allowing easy installation and simplifying the diagnostic process. An onboard LED provides visual alerts to help when a number of DCM’s are banked in close proximity to one another.

High quality connectors simplify the installation process and allow simple drop in replacement in the event of hardware failure. Board configuration is achieved via a small number of jumpers and requires no specialist tools.

TECHNICAL SPECIFICATIONS

Physical

 

Inputs continued

Break Glass Sense

 

 

 

Fire Alarm Sense

Size

 

 

Power Fail

- Board Only

180 x 120 x 20mm

 

Tamper

 

(7.1” x 4.7” x 0.8”)

 

Battery Low (reported internally)

- Enclosure

460 x 250 x 90mm

 

Dedicated Power Fail Input

 

(18” x 10” x 3.5”)

 

* = 4 state tamper protected inputs

Weight

 

Outputs

Two 12V or 24V open collector outputs

- Board Only 0.1Kg

 

 

limited to 1.5A

- Enclosure 5.00kg

 

 

(Door Lock and External Sounder)

Housing

Wall mounting 1.2mm steel enclosure

 

Two Relays rated at 35V@2A

Colour

Grey

Reader capacity

2 Weigand/Mag Stripe interfaces (data/

Power

 

 

data, clock/data)

- Board Only:

 

Configuration

Operational parameters are downloaded

- Voltage

11 – 15Vdc

from host computer.

 

- Current

 

Communication Interface

Consumption

300mA (excluding locks

 

and heads)

To Readers

Weigand/Mag Stripe interface (data/data,

Enclosure:

 

Voltage

220-230 VAC 50/60Hz.

 

clock/data)

Current

 

- Connection

2 part screw terminals

Consumption

450mA (excluding locks and heads)

To System Host

RS485 multidrop cable runs using copper

Backup Battery

Integral charging circuit provided with

 

wire with maximum length of 1.2km

 

enclosure and space battery

 

without repeater

 

(Battery not supplied).

- Connection

2 part screw terminals

Environmental

 

Product Codes

 

- Temperature

-20º to 70°C (-4° to 158°F)

 

- Humidity

95% non condensing

DCM/150/105

DCM 150 (Board Only)

LED Indicators

Power, Link to host, Comms Tx/Rx, Fault /

 

Tamper, Lock and Relay Status

DCM/150/101

DCM 150 (Includes enclosure, board &

 

 

 

power supply/battery charger)

Functionality

 

 

 

Inputs

* Door Position

 

 

 

* Lock Status

 

 

 

* Exit Push Button

 

 

 

* General Purpose

 

 

Product specifications and availability is subject to change without notice. Certain product names mentioned herein may be trade names and/or registered trademarks of their companies.

CEM Systems Ltd Unit 4 Ravenhill Business Park Ravenhill Road Belfast BT6 8AW Northern Ireland

www.cemsys.com

Tel: +44 (0)28 9045 6767 Fax: +44 (0)28 9045 4535 email: cem.sales@tycoint.com

Page 2
Image 2
Tyco DCM 150 Technical Specifications, Product Highlights, Connect to existing read head technology, Ease of Installation