CEM/A/051/ Rev B
Product Highlights
Host Communications
The DCM 300 has an
On-board Card Reading Technologies
The DCM 300 supports a wide range of head technologies using the two available
Off-line Card Validation
The card database is initially downloaded to the reader’s
memory from the host computer with subsequent changes to card data automatically sent as updates. This ensures that the reader has
Easy to Install
The DCM 300 is designed to be extremely easy to install.
The installer simply enters the units preconfigured IP address on the AC2000 workstation, provides it with power, connects to an Ethernet network and the reader
and receives up to 50,000 cardholder database in under 2 minutes.
TECHNICAL SPECIFICATIONS
Physical |
| |
Size | - Board Only | 192 x 145 x 20mm |
|
| (7.6” x 5.7” x 0.8”) |
| - Enclosure | 460 x 250 x 90mm |
|
| (18” x 10” x 3.5”) |
Weight | - Board Only | 0.1Kg |
| - Enclosure | 5.00kg |
Housing |
| Wall mount 1.2mm steel enclosure |
Colour |
| Grey |
Power | Board Only: |
|
| - Voltage | 9 – 14Vdc |
| - Current |
|
| Consumption | 170mA (excluding locks and heads) |
| Enclosure: |
|
| - Voltage | |
| - Current |
|
| Consumption | 200mA (excluding locks and heads) |
Backup Battery | Integral charging circuit provided with | |
|
| enclosure and space battery |
|
| (Battery not supplied) |
Environmental |
| |
| - Temperature | |
LED Indicators | Power, Link to host, Comms Tx/Rx, Fault / | |
Functionality | Tamper, Lock and Relay Status | |
| ||
Inputs |
| * Door Position |
|
| * Lock Status |
|
| * Exit Push Button |
* General Purpose
Power Fail
Tamper
Battery Low (reported internally) Dedicated Power Fail Input
* = 4 state tamper protected inputs
Outputs | Two Relays rated at 30V@5A |
| Two 12V open collector outputs |
| limited to 1.5A (Door Lock and |
| External Sounder) |
Reader capacity | 2 Weigand/Mag Stripe interfaces |
| (data/data, clock/data) |
Configuration | Operational parameters are downloaded |
| from host computer |
Database memory | 1GB SD Card |
Cardholders | Storage up to 200,000 cardholders |
| at the door |
Transactions | Up to 50,000 transactions in offline |
| operation |
RTC Battery Backup | 3.0V rechargeable Lithium- |
Configuration | Operational parameters are downloaded |
| from host computer |
Communication Interface | |
To Readers | Weigand/Mag Stripe interface |
| (data/data, clock/data) |
Connection | 2 part screw terminals |
To System Host | 10/100 |
| Unshielded twisted pair cable |
Connection | RJ45 |
Product Codes |
|
DCM/300/004 | DCM 300e (Board Only) |
DCM/300/101 | DCM 300e (Includes enclosure, board & |
| power supply/battery charger) |
Product specifications and availability is subject to change without notice. Certain product names mentioned herein may be trade names and/or registered trademarks of their companies.
CEM Systems Ltd Unit 4 Ravenhill Business Park Ravenhill Road Belfast BT6 8AW Northern Ireland | www.cemsys.com |
Tel: +44 (0)28 9045 6767 Fax: +44 (0)28 9045 4535 email: cem.sales@tycoint.com |