Tyco DIU 220 manual Diu

Models: DIU 220

1 2
Download 2 pages 40.92 Kb
Page 1
Image 1

DIU 220

Power over Ethernet Door Interface Unit

OVERVIEW

The DIU 220 (PoE Door Interface Unit) combines Ethernet communications and sufficient power to support a complete door set, including an In reader, Out reader and a standard 650mA maglock, over a single Cat5/6 cable. The DIU 220 eliminates the need to include a power supply unit (PSU) at the door and expense of providing mains power to the PSU.

The DIU 220 is designed primarily to provide power to a door lock, as well as local power to a CEM reader when a high level of security is required. It has onboard inputs which can be used to monitor conditions such as a fire alarm or activated break-glass condition.

The DIU 220 improves door security by allowing the installer to locate lock controls on the secure side of a door, with an intelligent CEM reader on the unsecured side. The DIU 220 communicates with an intelligent CEM reader via the readers slave communication channel. Upon a valid swipe at the card reader, the reader will instruct the DIU (over the communications channel) to activate the appropriate output to release the lock using a coded data signal (i.e. coded lock).

As an added benefit, the DIU 220 monitors the status of all standard door monitoring inputs; inputs on an intelligent CEM reader are free for use as general purpose inputs. The DIU 220 is supplied in a plastic enclosure complete with PoE backplane and an output for an additional door holder.

DIU 220

www.cemsys.com

FEATURES

Ethernet communications and power via a single Cat5/6 cable

Eliminates to need to have mains power and a PSU at the door

Provides local power for:

In reader

Out reader

Maglock

Sounder

Door Holder

11.5V @ 1.6A power output*

Door Interface Electronics held on one board

Provides ‘coded lock’ interface between door hardware and card reader

Fire alarm and break glass inputs for emergency door and holder release

Weigand interface for 3rd party exit reader.

Designed for ease of installation and maintenance using 2 part connectors throughout

Compliant with EN55022 (emissions) and EN55024 (access control immunity)

* 1.6A @ 23oC or 1.4A @55oC