KT-MOD-OUT16

KT-400 Expansion Module 16-Output with SPI Cable Install Sheet

3.4.Check the power jumper JP1 position. Put it on EXT if you need external power or INT if no external power is required.

3.5.Applying Power

After all wiring is completed, connect the 16 VAC to the KT-400. Connect the battery leads to the battery, and then apply power to the AC transformer.

Note: Do not connect the power until all wiring is complete.

Terminal Connections

Module no.: ______________________________________________________________________________________

Date of installation: _______________________________________________________________________________

KT-400 Name: ____________________________________________________________________________________

KT-400 SITE NAME: _______________________________________________________________________________

KT-400 Serial Number: _____________________________________________________________________________

AUX: ___________________________________________________________________________________________

SPI BUS (FROM): _________________________________________________________________________________

SPI BUS (TO): ____________________________________________________________________________________

O1:

 

O9:

_________________________________________

O2:

 

O10:

________________________________________

O3:

 

O11:

________________________________________

O4:

 

O12:

________________________________________

O5:

 

O13:

________________________________________

O6:

 

O14:

________________________________________

O7:

 

O15:

________________________________________

O8:

 

O16:

________________________________________

FCC & IC COMPLIANCE STATEMENT

CAUTION: Changes or modifications not expressly approved by Kantech could void your authority to use this equipment.

This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accordance with the manufacturer’s instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for Class A device in accordance with the specifications of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in any residential installation.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to television or radio reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Re-orient the receiving antenna

Relocate the alarm control with respect to the receiver

Move the alarm control away from the receiver

Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits.

If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet prepared by the FCC helpful: “How to Identify and Resolve Radio/Television Interference Problems”. This booklet is available from the U.S. Government Printing Office, Washington, D.C. 20402, Stock # 004-000-00345-4. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation. This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. The KT-400 is also compliant with EN55022: 1994, amendment 1: 1995, Class A.

Tel.: 1 (450) 444 2030 • Toll Free: 1-888-222-1560 • Fax: 1 (450) 444 2029 • Internet: www.kantech.com

DN1781-0809

Copyright © 2008 Tyco International Ltd. and its Respective Companies. All Rights Reserved. • Specifications may change without notice.

Kantech and the Kantech logo are trademarks of Tyco International Ltd. and its Respective Companies.

Page 2
Image 2
Tyco KT-MOD-OUT16 specifications Terminal Connections, FCC & IC Compliance Statement

KT-MOD-OUT16 specifications

The Tyco KT-MOD-OUT16 is an advanced modular output card specifically designed for use in industrial and commercial applications. As part of the KT series from Tyco, this module offers a versatile solution for controlling multiple outputs, making it an essential component for various automation systems.

One of the standout features of the KT-MOD-OUT16 is its capacity to control up to 16 outputs. Each output can be independently programmed and controlled, providing flexibility for users in diverse applications. This capability makes the module suitable for managing various devices, such as motors, lights, and sensors, thereby streamlining operations in complex systems.

The module employs reliable solid-state output technology, which enhances its durability and performance. This technology minimizes wear and tear compared to traditional electromechanical relays, leading to a longer operational lifespan. Additionally, solid-state outputs can handle high switching frequencies, making the KT-MOD-OUT16 ideal for high-speed applications.

In terms of communication, the KT-MOD-OUT16 supports various protocols, ensuring compatibility with a wide array of control systems. This includes both serial and parallel communication options, allowing seamless integration into existing setups. Such flexibility reduces installation time and simplifies future upgrades or expansions.

Another significant characteristic of the KT-MOD-OUT16 is its comprehensive diagnostic capabilities. The module incorporates built-in monitoring features that provide real-time feedback on output status and health. This functionality enables quick troubleshooting and maintenance, minimizing downtime and ensuring continuous operation of critical systems.

The design of the module emphasizes ease of installation and use. It is compact and lightweight, allowing for efficient use of space within control panels. Furthermore, user-friendly configuration software simplifies the programming process, making it accessible even for those with limited technical expertise.

Overall, the Tyco KT-MOD-OUT16 is a powerful, reliable, and flexible output module that is well-suited for a wide range of industrial applications. With its impressive features, including solid-state technology, multiple communication options, and robust diagnostic capabilities, the KT-MOD-OUT16 stands out as an excellent choice for modern automation needs. It provides users with the tools necessary to streamline their operations, enhance system performance, and ultimately achieve greater efficiency.