s p e c i f i c a t i o n s
General
Dimensions (H x W) . . | .11.0 x 15.0 cm (4.3 x 5.9 in) |
Environmental . . . . | .0° to 50° C (32° to 122° F); 5 to 85% relative |
| humidity, |
Power Input Voltage . | . 12 VDC +/- 10% |
Tamper | .Dedicated input for external tamper switch |
Weight | .0.23 kg (8 oz) |
Regulatory | . UL 294, UL 1076, FCC Part A |
| CE, EN 50133, ROHS |
I8 Input Module
Power Requirements . . 180 mA @ 12 VDC Inputs . . . . . . . . Eight Class A supervised
LEDs per Input . . . . .Red (alarm), green (normal), and yellow (supervision error)
I8-CSI Input Module
Power Requirements . . 80 mA @ 12 VDC
Inputs . . . . . . . . Eight Class A supervised, configurable via DIP switch LEDs per Input . . . . .Red (alarm), green (normal) and yellow
(supervision error)
Circuits Supported . . . Single resistor: 1K, 5K, 10K Double resistor: 1K, 5K, 10K, 1K/2K, 6.8K/18K, 200/10K Unsupervised: NO, NC
R8 Output Module
Power Requirements . . 45 mA @ 12 VDC plus 32 mA per active relay Outputs . . . . . . . Eight Form C dry contact relays
LED per Output . . . . Red (relay active) Relay Contact Ratings . .30 VDC, 2.0 A resistive
30 VDC, 1.0 A inductive
125 VAC, 4.0 A
Optional Metal Enclosures with Tamper Switch
Dimensions . . . . . 356 x 305 x 89 mm (14 x 12 x 3.5 in) Capacity . . . . . . Up to four input or output modules
Dimensions . . . . . 210 x 184 x 83 mm (8.25 x 7.25 x 3.25 in) Capacity . . . . . . One input or output module
Model Numbers
Wiring Summary
Signal | From | To | Belden # | Gauge | # of Pairs | Shielded | Maximum Length | |
|
|
|
|
|
|
|
| |
Comm | apC/iSTAR | I8/R8 | 9841* | 24 | 1 | Yes | 1,220 m | |
(4,000 ft) | ||||||||
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| |
Power | apC/iSTAR | I8/R8 | 9841* | 24 | 1 | No | Based on | |
voltage drop | ||||||||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
Control Point | R8 | Strike, Siren, etc. | 8442/8461 | 18 | 1 | No | Based on | |
voltage drop | ||||||||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
Supervised Input | I8 | REX or Door Contact | 8442/8461 | 22/18 | 1 | No | 610 m (2,000 ft) | |
|
|
|
|
|
|
|
|
Wiring Configuration Diagram
1 2 3 4 P9
P10 | P9 | ON = LED Power | |
ON = Disable Tamper | |||
|
| ON = Not Used | |
|
| ON = 485 Termination |
Configuration
P1
3C
2NC
W1
NO 1P8
NC 2
Configuration
P1
INA
DS4
1 DS3
| 1 |
| 1 |
|
|
|
|
DS1 | TS | GND | +12V +D |
| GND | DS25 | |
|
|
| 1 | 2 | 3 | 4 |
|
|
|
|
|
|
| ON | DS24 |
|
|
|
| S1 |
| DS23 |
P8
1 |
INH |
P2
1 NO
C3P7
DS2
S1 |
NO |
S3 |
S3 |
4 |
3 |
2 |
I8 Input Module Configuration
R8 Output Module
P3
P4
3C
2NC
1 NO
3 C
2NC
1 NO
3 C
2NC
1 NO
R8 OUTPUT MODULE
SOFTWARE HOUSE
MADE IN USA
TAMPER
INPUT
2 3 4 5 | 6 |
|
1 | 7 | SW1 |
FE DC B A9 | ||
0 | 8 |
|
NOTE: All mounting holes are 1/8" dia. Max. component height 1/2".
NO 1
NC 2
C3
NO 1P6
NC 2
C3
P5
NO 1
NC 2
C3
P2
INB
DS7
1 DS6
DS5
P3
INC |
|
| DS10 |
1 | DS9 |
| DS8 |
P4
IND
DS13
1 DS12
DS11
ASSEMBLED IN USA
C COPYRIGHT 2007
|
|
|
|
| DS27 | DS26 |
| |
|
|
|
|
|
|
|
| DS22 |
|
|
| Y1 |
|
|
| ||
|
|
|
|
|
| U3 | DS21 | |
|
|
|
|
|
|
|
| DS20 |
|
|
|
|
|
| FOR SWH STD 1K DUAL |
| |
|
|
|
|
|
| SEE QUICKSTART DOC FOR OTHER SETTINGS |
| |
|
|
|
|
|
| CYCLE POWER AFTER SETTING |
| |
|
|
|
|
|
|
|
| DS19 |
| "WARNING Damage may result from incorrectly |
| DS18 | |||||
| wiring power terminals, input and output lines, and |
| DS17 | |||||
|
|
| ||||||
| connections before powering the unit." |
| S2 | |||||
|
|
|
|
|
|
| ON | |
1 |
|
|
|
|
| |||
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| DS16 |
|
|
|
|
|
|
|
| DS15 |
|
| SW1 | Input Rating P9 | DS14 | ||||
TYCO | 12VDC 125mA |
| ||||||
SOFTWARE HOUSE® | Refer to Quick Start Installation Guide, | |||||||
P/N |
|
1 | P7 |
| 1 |
| ING |
| P6 |
| 1 |
| INF |
S2 |
|
4 |
|
3 |
|
2 |
|
1 | P5 |
| |
| 1 |
| INE |
Pb
Sample System Configuration: Combination Bus/Star Wiring Diagram
(*) For plenum or underground applications, use Belden 89182 for one pair 22 AWG, 100 ohm 12.95 pf/ft. Note: Control, supervised, and unsupervised input cables must be shielded for FCC Class B operation.
Product offerings and specifications are subject to change without notice. Actual products may vary from photos. Not all products include all features. Availability varies by region; contact your sales representative. Certain product names mentioned herein may be trade names and/or registered trademarks of other companies.
© 2008 Tyco International Ltd. and its respective companies. All rights reserved.
www.swhouse.com