s p e c i f i c a t i o n s

General

Dimensions (H x W) . .

.11.0 x 15.0 cm (4.3 x 5.9 in)

Environmental . . . .

.0° to 50° C (32° to 122° F); 5 to 85% relative

 

humidity, non-condensing

Power Input Voltage .

. 12 VDC +/- 10%

Tamper

.Dedicated input for external tamper switch

Weight

.0.23 kg (8 oz)

Regulatory

. UL 294, UL 1076, FCC Part A

 

CE, EN 50133, ROHS

I8 Input Module

Power Requirements . . 180 mA @ 12 VDC Inputs . . . . . . . . Eight Class A supervised

LEDs per Input . . . . .Red (alarm), green (normal), and yellow (supervision error)

I8-CSI Input Module

Power Requirements . . 80 mA @ 12 VDC

Inputs . . . . . . . . Eight Class A supervised, configurable via DIP switch LEDs per Input . . . . .Red (alarm), green (normal) and yellow

(supervision error)

Circuits Supported . . . Single resistor: 1K, 5K, 10K Double resistor: 1K, 5K, 10K, 1K/2K, 6.8K/18K, 200/10K Unsupervised: NO, NC

R8 Output Module

Power Requirements . . 45 mA @ 12 VDC plus 32 mA per active relay Outputs . . . . . . . Eight Form C dry contact relays

LED per Output . . . . Red (relay active) Relay Contact Ratings . .30 VDC, 2.0 A resistive

30 VDC, 1.0 A inductive

125 VAC, 4.0 A

Optional Metal Enclosures with Tamper Switch

RM-DCM-CAN

Dimensions . . . . . 356 x 305 x 89 mm (14 x 12 x 3.5 in) Capacity . . . . . . Up to four input or output modules

RM-CAN

Dimensions . . . . . 210 x 184 x 83 mm (8.25 x 7.25 x 3.25 in) Capacity . . . . . . One input or output module

Model Numbers

AS0073-001 . . . . . I8 input module AS0073-CSI . . . . . .I8-CSI input module AS0074-000 . . . . . . . . . . .R8 output module

RM-DCM-CAN . . . . .Large metal enclosure with tamper switch RM-CAN . . . . . . .Small metal enclosure with tamper switch

Wiring Summary

Signal

From

To

Belden #

Gauge

# of Pairs

Shielded

Maximum Length

 

 

 

 

 

 

 

 

Comm

apC/iSTAR

I8/R8

9841*

24

1

Yes

1,220 m

(two-wire RS485)

(4,000 ft)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

apC/iSTAR

I8/R8

9841*

24

1

No

Based on

voltage drop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control Point

R8

Strike, Siren, etc.

8442/8461

18

1

No

Based on

voltage drop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supervised Input

I8

REX or Door Contact

8442/8461

22/18

1

No

610 m (2,000 ft)

 

 

 

 

 

 

 

 

Wiring Configuration Diagram

1 2 3 4 P9

P10

P9

S1-1

ON = LED Power

S1-2

ON = Disable Tamper

 

 

S1-3

ON = Not Used

 

 

S1-4

ON = 485 Termination

Configuration

P1

3C

2NC

W1

NO 1P8

NC 2

Configuration

P1

INA

DS4

1 DS3

 

1

 

1

 

 

 

 

DS1

TS

GND

+12V +D

 

-D

GND

DS25

 

 

 

1

2

3

4

 

 

 

 

 

 

 

ON

DS24

 

 

 

 

S1

 

DS23

P8

1

INH

P2

1 NO

C3P7

DS2

S1

NO

S3

S3

4

3

2

I8 Input Module Configuration

R8 Output Module

P3

P4

3C

2NC

1 NO

3 C

2NC

1 NO

3 C

2NC

1 NO

R8 OUTPUT MODULE

AS-0074-000 REV.A

SOFTWARE HOUSE

MADE IN USA

TAMPER

INPUT

2 3 4 5

6

 

1

7

SW1

FE DC B A9

0

8

 

NOTE: All mounting holes are 1/8" dia. Max. component height 1/2".

NO 1

NC 2

C3

NO 1P6

NC 2

C3

P5

NO 1

NC 2

C3

I8-CSI Input Module

P2

INB

DS7

1 DS6

DS5

P3

INC

 

 

DS10

1

DS9

 

DS8

P4

IND

DS13

1 DS12

DS11

ASSEMBLED IN USA

C COPYRIGHT 2007

 

 

 

 

 

DS27

DS26

 

 

 

 

 

 

 

 

 

DS22

 

 

 

Y1

 

 

 

 

 

 

 

 

 

U3

DS21

 

 

 

 

 

 

 

 

DS20

 

 

 

 

 

 

FOR SWH STD 1K DUAL S2:3-4, S3:1-4 = OFF

 

 

 

 

 

 

 

SEE QUICKSTART DOC FOR OTHER SETTINGS

 

 

 

 

 

 

 

CYCLE POWER AFTER SETTING

 

 

 

 

 

 

 

 

 

DS19

 

"WARNINGDamage may result from incorrectly

 

DS18

 

wiring power terminals, input and output lines, and

 

DS17

 

central-supervising station lines. Check all

 

 

 

connections before powering the unit."

 

S2

 

 

 

 

 

 

 

ON

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DS16

 

 

 

 

 

 

 

 

DS15

 

 

SW1

Input Rating P9

DS14

TYCO

12VDC 125mA

 

SOFTWARE HOUSE®

Refer to Quick Start Installation Guide,

18–CSI BOARD

0312–5008–01 Rev.

P/N UM-218, Rev B0, July 2008

 

1

P7

 

1

 

ING

 

P6

 

1

 

INF

S2

 

4

 

3

 

2

 

1

P5

 

 

1

 

INE

Pb

Pb-Free

Sample System Configuration: Combination Bus/Star Wiring Diagram

(*) For plenum or underground applications, use Belden 89182 for one pair 22 AWG, 100 ohm 12.95 pf/ft. Note: Control, supervised, and unsupervised input cables must be shielded for FCC Class B operation.

Product offerings and specifications are subject to change without notice. Actual products may vary from photos. Not all products include all features. Availability varies by region; contact your sales representative. Certain product names mentioned herein may be trade names and/or registered trademarks of other companies.

© 2008 Tyco International Ltd. and its respective companies. All rights reserved. SH0146-DS-200810-R01-LT-EN

www.swhouse.com

Page 2
Image 2
Tyco AS0074-000, RM-DCM-CAN General, I8 Input Module, I8-CSI Input Module, R8 Output Module, Model Numbers, Wiring Summary

AS0074-000, AS0073-001, RM-CAN, RM-DCM-CAN, AS0073-CSI specifications

Tyco AS0074-000, AS0073-001, RM-DCM-CAN, RM-CAN, and AS0073-CSI constitute a suite of highly regarded automotive and industrial connectivity solutions designed to meet the needs of a rapidly evolving market. These products are engineered with cutting-edge technologies to ensure reliability, versatility, and high performance in demanding environments.

The Tyco AS0074-000 is a robust connector that excels in high-performance applications. It features a high-density pin configuration that allows for optimized space utilization, making it perfect for compact automotive designs. The connector supports high current ratings and boasts excellent electrical performance, ensuring low contact resistance and minimal voltage drops. Additionally, its durable housing is engineered from premium materials to withstand harsh environmental conditions, providing robust protection against moisture, vibrations, and mechanical stress.

Similarly, the AS0073-001 connector is notable for its versatility. This connector serves multiple applications within automotive electronics, from infotainment systems to power distribution. With a simplified mating mechanism, users benefit from quick and easy connections and disconnections, reducing assembly time and enhancing productivity. Its coding features prevent misalignment, ensuring reliable signal integrity and system performance even in challenging operational scenarios.

The RM-DCM-CAN and RM-CAN models are essential for industries concerned with Controller Area Network (CAN) communication. These devices facilitate seamless data exchange between electronic control units (ECUs) in vehicles, enhancing system diagnostics and monitoring capabilities. The RM-DCM-CAN is designed with advanced shielding technologies that reduce electromagnetic interference, ensuring stable communication over long distances. Its integration with advanced protocols adds layers of security and reliability.

The RM-CAN, an equally vital component, focuses on high-speed data transmission, promoting faster processing and response times in vehicular systems. Engineered for flexibility, this model can integrate into various applications, from automotive to industrial controls, showcasing its adaptability across numerous platforms.

Finally, the AS0073-CSI connector pairs high performance with security and reliability essential for safety-critical applications. With robust terminals and an advanced locking mechanism, it guarantees stable connections, minimizing any risk of accidental disconnections during operation.

In summary, these Tyco connectors and modules represent a blend of advanced technologies and user-focused design features, leading to enhanced performance, reliability, and versatility across a spectrum of automotive and industrial applications.