N5D, N5DH, N5DL, N5DSC | Tyler Refrigeration |
Top Duct
1.Remove shelves and shelf brackets, see page 15.
2.Remove screws, rear retainer plate and honeycomb grid sections from top of case.
3.Remove screws and top duct from case.
4.After cleaning, replace top duct and remaining components in reverse order.
Lower Cladding
1.Remove front kickplate form kickplate supports. (See
2.Remove mounting screws from top and bottom of lower cladding and remove lower cladding.
3.After cleaning, replace in reverse order.
Upper Cladding
1.Remove lower cladding, see this page.
2.Remove color band, bumper and bumper retainer from the case. (See General- UL/NSF I&S Manual.)
3.Remove screws for top and bottom of upper cladding and remove upper cladding.
4.After cleaning, replace upper cladding and remaining front components in reverse order.
GENERAL INFORMATION
NSF Product Thermometer Installation
1.Unwrap the thermometer and bracket assembly shipped loose with the case.
2.Position bracket in front right corner of the
3.Drill two .196” holes in the bottom tray.
NOTE
For ease of installation, position the wash- ers and capnuts on the top side of the bracket and bottom tray.
4.Mount the bracket to the bottom tray with two screws, washers and capnuts.
Page 16 | May, 2004 |