4 Product Operation

Air Flow

IMPORTANT

The unit requires proper air flow to perform at its highest efficiency. Do not block the front grille or internal fans at any time, or the unit will not perform as expected. Do not install the unit behind a door.

Initial Startup

All U-Line controls are preset at the factory. Initial startup requires no adjustments.

IMPORTANT

U-Line recommends allowing the unit to run overnight before loading refrigerator or freezer with product.

To turn the unit on or off, press and hold the POWER icon (1) for about ten seconds and release. The display will show the unit set- point temperature when turned on and display OFF when the unit is off.

Electronic Control Panel

Digital Display. Dual Zone Wine Captain Models provide two controlled temperature zones to satisfy the specific storage requirements of your finest wines.

The electronic control with dual digital displays shows a single continuous set-point temperature for each zone. This set point is a base number used by the controller to maintain the multiple temperature zones in the unit. The factory default set-point for Wine Captain models is 50°F. The set-point temperature is a gauge for further temperature adjustments.

Turning the Display Off. Wine Captain Models have a DISPLAY OFF mode available through the control panel. This allows you to control if the display (4 & 5) will be ON or OFF with the door closed. The icon sequence that follows will switch between both modes, On or Off:

1.Press and hold the WARMER icon (2), and simultaneously within five seconds press the ON OFF icon (1) three times.

2.The display will be either visible or dark with the door closed. To return to the previous mode, repeat Step 1.

Dual Temperature Zones

To adjust the set point temperature:

Your unit has been designed to provide two temperature zones (upper and lower) in the cabinet. Each zone can be adjusted within the 4 following temperature ranges:

Wine Captain Temperature Ranges

 

Default

Range

RW (Red Wine)

55°F

60° - 50°F

WW (White Wine)

50°F

55°F - 45°F

SW (Sparkling Wine)

45°F

50° - 40°F

BV (Beverage)

38°F

60° - 34°F

5

6

7

8

 

UPPER ZONE CONTROLS

 

 

 

 

 

 

 

 

Power Warmer Cooler Display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Display Warmer Cooler Light

LOWER ZONE CONTROLS

1 2 3 4

1.Press and release the desired zone Warmer (2 or 6) icon to put the controller in the SET TEMPERATURE mode. The current range symbol will show on the display. (4 or 5)

2.Within five seconds press the WARMER or COOLER icon to scroll to the desired range (RW, WW, SW, BV).

3.When the desired range is displayed, press the LIGHT (8) icon to display the current set-point temperature.

4.Press the WARMER (2 or 6) or COOLER (3 or 7) icon as required to adjust the set-point temperature.

5.When the desired set-point is displayed, press the LIGHT (8) icon. The new set-point will show in the display.

6.Repeat for other zone if desired.

Temperature °F °C Selection. U-Line products supplied for 110 VAC have temperatures displayed (4 & 5) default in Fahrenheit (°F). Models supplied for 220 VAC have temperatures displayed (3) default in Celsius (°C).

Easily adjust the display for either type temperature display.

Press and hold the LIGHT icon (8) and simultaneously within five seconds press the COOLER icon (5) three times to change the display (3) as needed.

Temperature Display. Under normal operating conditions the temperatures will fluctuate based on a number of factors. On passive cooled units the temperature will always be cool toward the top and coolest toward the bottom.

To display actual temperature:

1.Press the desired zone WARMER icon (2 or 6) for five seconds. The display (4 or 5) will indicate the actual temperature.

2.After about 5 seconds, the set point temperature will return to the display.

U-Line Product Operation

5

Page 7
Image 7
U-Line 2275ZWCOL manual Air Flow, Initial Startup, Electronic Control Panel, Dual Temperature Zones, Product Operation