STORAGE, VACATION AND MOVING
If the unit is to be stored, moved or not used for extended periods, it will be necessary to drain the system of water.
! WARNING !
Electrical Shock Hazard. Disconnect power before servicing. Before operating replace all panels. Failure to do so can result in death or electrical shock.
1.Disconnect power from the unit.
2.Remove ice from the storage bin.
3.Shut off water supply at the main water source.
4.Remove grille (1 screw).
5.Remove the front access panel (2 screws) (see Figure 4).
6.Disconnect the inlet and out- let lines to the water valve and allow them to drain (see Figure 34).
WATER
7. Reconnect inlet and outlet OUTLET lines to the water valve.
8. Replace front access panel. | WATER | |
INLET | ||
|
9.Replace grille.
10.Drain water from the water trough and drain line by
removing the overflow | tube | UL204D |
|
| |
(see Figure 33). |
| Figure 34 |
11.Clean the ice maker and storage bin before next use.
12.Reconnect power.
27