SERVICING

Design Features Performance

CompressorCOMP

To energize the compressor touch the previously disconnected pink lead back to the board. You should hear the compressor start up and the green COMP light will illuminate. If it does not start check voltage at the compressor and at the output from the board. If the green light does not illu- minate first remove both pink wires from the board and directly jump the two spade connectors together. If the light does not illuminate still then the board is defective. If the light does illuminate there is an open pump overflow circuit. This circuit should only be open when the P60 pump is overfilled with water. This would signal a defective pump or blocked drain line. When doing this do not start and stop the compressor frequently or the compressor overload protect will trip.

Hot gas valve

Hot Gas

Make sure the pink lead is disconnected from the board before beginning this procedure. Turn the power switch to the on/ice position. You should hear the hot gas valve click and the green HOT GAS light should illuminate. If the valve does not operate but the green light comes on check volt- age at the valve and board output. If the green light does not illuminate first check the On/Off/Cln switch for continuity. If the switch is operating properly and set to the on position the green HOT GAS light should be illuminated.

Water valve

H20 IN

Make sure the pink lead is disconnected from the board before beginning this procedure and the power switch is still in the off position. Turn the switch to the CLN position. The water valve should energize and the H20 IN green light should illuminate. You should see water filling into the trough. If water is not filling but the green light is on check voltage at the valve and board output. Also, verify that the water supply is hooked up and turned on. If the light does not illuminate check the Cln switch for continuity. If the switch is operating properly and set to the CLN position the green H20 IN light should be illuminated.

Refrigeration valve

REF VLV

Condenser fan

COND FAN

Water circulation pump

H20 PUMP

Before beginning this ensure the pink lead is disconnected from the board and the switch is in the off position.

Turn ice thickness adjustment dial to +2 setting. This should energize the REF VLV relay and illumi- nate the green REF VLV light. You should hear the valve click and it should feel warm to the touch. Continue turning the dial to the “0” setting. At this point the condenser fan should activate and the green COND FAN light will illuminate. Finally, turn the dial to -2 and the water circulation pump will energize. If there is water in the trough the pump should begin to pump water over the ice- mold. If the water is low the pump may not pump water but make splashing noise only.

At the conlusion of this testing:

1.Disconnect power supply to unit.

2.Connect both pink leads to the circuit board.

3.Remove jumper to thermistor pins 9 and 10. See page 39 for pin locations.

4.Turn ice thickness adjustment dial to the “0” setting.

5.Connect power to the unit.

6.Turn power switch to the ice position.

28

Page 28
Image 28
U-Line CLRCO2075 manual CompressorCOMP, Hot gas valve, Water valve H20, Refrigeration valve, Condenser fan

CLRCO2075 specifications

The U-Line CLRCO2075 is a high-performance undercounter refrigerator that stands out for its sleek design and versatile functionality. Tailored for both residential and commercial use, this unit exemplifies quality craftsmanship. With a contemporary stainless-steel finish, it seamlessly integrates into any modern kitchen or bar area, elevating the overall aesthetic.

One of the standout features of the CLRCO2075 is its generous storage capacity. It boasts an impressive 5.2 cubic feet of internal space, which can accommodate a wide array of beverages and food items. The refrigerator is designed with adjustable shelves, allowing users to customize the layout to fit their specific storage needs. This flexibility is complemented by a uniquely designed door, which includes a full-length glass panel that not only enhances visibility but also adds a touch of elegance.

Equipped with advanced cooling technologies, the U-Line CLRCO2075 ensures that items are kept at optimal temperatures. The unit employs a dynamic cooling system, which allows it to cool down rapidly and maintain consistent temperatures throughout the interior. This technology ensures that beverages remain refreshingly cold, making it an ideal choice for entertaining guests.

The U-Line CLRCO2075 features user-friendly controls, including a digital touchpad that provides precise temperature settings and easy access to additional functionalities. This includes an integrated alarm system that alerts users if the door is left ajar, which helps to prevent temperature fluctuations and conserve energy.

Another notable characteristic of this refrigerator is its energy efficiency. Designed with eco-friendly principles in mind, the CLRCO2075 meets stringent Energy Star ratings, contributing to reduced energy consumption. This helps not only in lowering electric bills but also in promoting sustainable living practices.

In summary, the U-Line CLRCO2075 is a remarkable addition to any space, combining style, performance, and efficiency. Its ample storage, advanced cooling technologies, user-friendly features, and energy-efficient design make it an excellent choice for those seeking a reliable undercounter refrigerator. Whether for personal or professional use, it meets diverse refrigeration needs while enhancing the overall look of your environment.